Instructions – Parts List AIR DRIVEN Twistorkt Helix Mixer 308175P 100 psi (0.7 MPa, 7 bar) Maximum Working Pressure Model 224854, Series D Carbon Steel Agitator Model 235534, Series D Stainless Steel Agitator Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbols Warning Symbol Caution Symbol WARNING CAUTION This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions. WARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. INSTRUCTIONS D This equipment is for professional use only.
WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D Ground all equipment. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric shock while using this equipment, shut off the agitator immediately. Do not use the equipment until you identify and correct the problem.
Installation WARNING FIRE AND EXPLOSION HAZARD Always maintain a minimum of 1 in. clearance between rotating agitator parts and container to prevent sparks from contact. Installing the Agitator 1. Install the agitator on the container cover by screwing the helix through the drum bung hole and screwing the agitator housing into the bung hole. Refer to the Dimension Drawing on page 11.
Installation Grounding Proper grounding is an essential part of maintaining a safe system. C To reduce the risk of static sparking, all electrically conductive objects or devices in the spray area must be properly grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. To ground the agitator: Remove the grounding screw (A) and lockwasher (B). See Fig. 2. Secure the ground wire terminal (C) to the agitator with the screw and lockwasher.
Operation WARNING MOVING PARTS HAZARD To reduce the risk of serious injury, including cuts, amputation of fingers, and splashing in the eyes or on the skin: D Always shut off the mixer and disconnect the air line before checking or repairing the mixer. Operating the Agitator 1. Fill the fluid supply container. CAUTION Do not operate the agitator at a high speed for a long period of time.
Service WARNING MOVING PARTS HAZARD To reduce the risk of serious injury, including cuts, amputation of fingers, and splashing in the eyes or on the skin: D Always shut off the mixer and disconnect the air line before checking or repairing the mixer. D Wear eye protection. WARNING FIRE AND EXPLOSION HAZARD To prevent an explosive hazard, where injury and/or property damage can result: D Do not operate this air motor with combustible gases. D Do not use kerosene or other flammable solvents to flush unit.
Parts Model 224854 Twistorkt Helix Mixer Carbon Steel, Includes items 1 to 22 0911B 11f 11a 11b 11e 11c 11d Ref. No. 11 Needle Valve Includes items 11a–11f 2 1 1a 22 20 4 16 1 3 11 10 17 4 1 3 6 5 9n 7 n8 8 308175 1 Torque to 80–100 in-lbs (9–11.3 NSm). 2 Apply medium grade sealant to external threads. 3 Torque to 34–40 in-lbs (4–4.5 NSm). Be sure air motor shaft bottoms out in mounting hole before tightening. 4 Align as instructed on page 7.
Parts Model 224854 Twistorkt Helix Mixer Carbon Steel, Includes items 1 to 22 Ref. No. 1* 1a 3 4 5 6 7 8n 9n 10 Part No. 111310 113779 101682 224876 224852 224393 187054 101946 111312 112364 11 206264 11a 166529 Description Qty. MOTOR, air; Includes item 1a S MUFFLER, exhaust SCREW, cap, sch; 1/4–20 x 0.625 HOUSING, outlet, carbon steel SHAFT, agitator HELIX, agitator PLUG, fluid tube PIN, cotter O-RING, Fluoroelastomer SCREW, set, socket; 1/4–20 UNC 3A VALVE, needle Includes items 11a to 11f .
Parts Model 235534 Twistorkt Helix Mixer 0911B 11f Stainless Steel, Includes items 1 to 22 11a 11b 11c 11e 11d Ref. No. 11 Needle Valve Includes items 11a–11f 2 1 1a 22 20 4 16 1 3 11 10 17 4 1 3 6 5 9n 7 n8 10 308175 1 Torque to 80–100 in-lbs (9–11.3 NSm). 2 Apply medium grade sealant to external threads. 3 Torque to 34–40 in-lbs (4–4.5 NSm). Be sure air motor shaft bottoms out in mounting hole before tightening. 4 Align as instructed on page 7.
Parts Dimensions Model 235534 Twistorkt Helix Mixer Stainless Steel, Includes items 1 to 22 Ref. No. Part No. 1* 1a 3 4 5 6 7 8n 9n 10 111310 113779 101682 235535 235530 224393 187054 101946 111312 112364 11 206264 11a 11b 11c 11d 11e 11f 16 17 166529 166532 164698 157628 165722 166531 187577 102023 20 111593 22 157021 * Description Qty. MOTOR, air; Includes item 1a S MUFFLER, exhaust SCREW, cap, sch; 1/4–20 x 0.
Technical Data Maximum Working Pressure . . . . . . . . . 100 psi (7 bar) Maximum Recommended Agitator Speed . . . . 800 rpm Air Consumption At 800 rpm with 100 psi (7 bar) air inlet pressure: 5 scfm (0.14 m#/min.) At 400 rpm with 100 psi (7 bar) air inlet pressure: 2 scfm (0.06 m#/min.) Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.6 lb (8 kg) Wetted Parts Model 224854 . . . Carbon Steel, Fluoroelastomer, Acetal Model 235534 . . . . . .
Notes 308175 13
Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.