Instructions – Parts List PRESIDENT HYDRA-CATr FIXED RATIO Proportioning Pumps 308224H EN 3000 psi (21 MPa, 210 bar) Maximum Working Pressure Two or Three Displacement Pump Models in Various Mix Ratios, Pressure Ratios, and Flow Volume Available as Bare Pumps, or as Wall-Mounted* or Free-Standing Models *Includes Mixing Manifolds, Automatic Pressure Relief Valves, Check Valves, Pressure Gauges, and Regulators. For models that are see pages 6 and 7.
Table of Contents Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 List of Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Installation – Optional Fluid Heaters . . . . . . . . . . . . . .
Symbols Warning Symbol Caution Symbol WARNING CAUTION This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions. WARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. D This equipment is for professional use only.
WARNING INJECTION HAZARD Spray from the valve, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. D Fluid injected into the skin is a serious injury. The injury may look like just a cut, but it is a serious injury. Get immediate medical attention. D Do not point the valve at anyone or at any part of the body.
WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Ground the Pumps on page 10. D If there is any static sparking or you feel an electric shock while using this equipment, stop spraying immediately. Do not use the equipment until you identify and correct the problem.
List of Models Pressure and Ratio Ratings for President Pumps WARNING To reduce the risk of over pressurizing a component, which can result in an explosion and serious injury, never operate the system at a working pressure higher than the lowest rated component in the system. All fluid side components such as dispensing valves, regulators, and hoses must have a working pressure equal to or greater than the pressure given in Column B for each pump model.
List of Models Models with Three Displacement Pumps Model No. Mix Ratio A B Maximum Pump Fluid Pressure at 100 psi (7 bar) Air Minimum Component Working Pressure Bare Wall Stand psi bar psi bar 2:1 231657** 231607** 231632** 1280 88 1800 124 2:1 231658** 1707 118 1800 4:1 231663** 1024 71 1150 **CE approved and 231613** 231638** Normal Pressure Ratio (Fluid to Air) Nominal Flow Volume @ 40 cpm gpm lpm 12.80 1.50 88 124 17.07 1.12 118 79 10.24 1.
Typical Installation NOTE: When pressure feeding the proportioning pump, mount fluid pressure gauges (J) at the proportioning pump inlets to monitor proper adjustment of the feed pump pressures. Never exceed 25% of the Hydra-Cat pump outbound fluid pressure on the feed supply. About the Typical Installations These pumps are designed to be part of a Hydra-Cat dispensing system that will proportion, mix, and dispense two-component fluids.
Typical Installation NOTE: When pressure feeding the proportioning pump, mount fluid pressure gauges (J) at the proportioning pump inlets to monitor proper adjustment of the feed pump pressures. Never exceed 25% of the Hydra-Cat pump outbound fluid pressure on the feed supply. About the Typical Installations These pumps are designed to be part of a Hydra-Cat dispensing system that will proportion, mix, and dispense two-component fluids.
Installation Bare Pumps Bare pumps are available for those installations which require a highly customized system. For a safe and efficient system, Graco recommends that the air and fluid components supplied with the Wall Mount and Cart Mount models also be used in customized systems. Refer to the Parts Drawings on pages 26–37 for part numbers. In addition, the accessories shown in the Typical Installation drawings and discussed in the following pages of this manual should be used.
Installation Air Control Accessories Automatic Pressure Relief Valves Install the accessories in the order shown in Fig. 4. Mount only the air regulator (E) and a master air valve (A) at the pump. Mount all other accessories on separate wall brackets to reduce stress on the pump inlet. Note that one air filter (B) can serve multiple pumps by using an air manifold downstream from the air filter.
Installation DD NOTE: If you mount the pump on a wall, turn the displacement pump inlet assemblies (CC) to face forward, rather than backwards as shown in Fig. 6. EE 37B Connect Fluid Supply Hoses RES For Two Displacement Pump Models HARD 1. Connect the resin supply hose (EE) to the 3/4 npt swivel inlet (37B) for the resin displacement pump. See Fig. 6. 37A 2. Connect the hardener supply hose (DD) to the 3/4 npt swivel inlet (37A) for the hardener displacement pump. See Fig. 6. CC 02889 Fig.
Installation – Optional Fluid Heaters All Models NOTE: For systems requiring one heater for each fluid, see page 38 to order the heaters and required plumbing (items 201 to 205). 201a 201b 201 202 204 OUT 1. Mount a heater to each side of the mounting bracket using the three screws (201a) and lockwashers (201b) supplied with each heater. See Fig. 8. 2. Connect a swivel union (202) to the outlet of each heater. See Fig. 8. IN 3. Connect a swivel union (203) to the inlet of each heater. See Fig. 8.
Installation – Optional Fluid Heaters 23 (N) 204B 205A FA RES RES HARD 17A 202A FB HARD 17B RES HEATE R OUT RES HARD RES IN 202B HARD HEATE R OUT IN 203A 203B 02894 Fig. 10 For Three Displacement Pump Models 16A 17A NOTE: You must provide two hoses (FA, FB in Fig.10) and fittings to run from the heater outlets to the mixer manifold inlets. 17B 16B NOTE: To accommodate two resin fluid hoses, the mixer manifold (23) must be disconnected from the bracket and mounted remotely. 3.
Installation – Optional Solvent Pump NOTE: The optional solvent pump is not offered as a kit; order parts as needed. The optional parts shown here are listed on page 39. These instructions assume that the pump is being mounted to the back of the stand offered in this manual. The Typical Installations on pages 8–9 show alternate installations. Adjust your installation according to your specific needs. 4. Couple the hose (303) and couplings (302). Connect the hose (303) to the adapter (301). 5.
Flushing When to Flush the System How to Operate the Mixer Manifold D Flush the system before its first use to remove the light oil which was left in after factory testing. To open or close the mixer manifold (N) fluid valves (LL) push the handle (KK) down to open and up to close. See Fig. 13. D Flush the manifold mixer (N), using the solvent pump, as frequently during the day as necessary to avoid exceeding the pot life limit of the material being pumped.
Flushing How to Flush the System WARNING If your system is equipped with heaters, always shut off the main power to the heaters before flushing. Circulate the fluid through the system for at least 10 minutes to cool the fluid and the heater. This reduces the risk of serious injury from burns. NOTE: For the first time flushing, we recommend using mineral spirits solvent (also called white spirit) to flush out the oil. Then flush again using a solvent that is compatible with the fluid you will be dispensing.
Operation Check the Drainage Bottles and Hoses WARNING WARNING Handling Plural Component Materials Be extremely cautious when handling plural component materials and solvents used with them. Some are extremely toxic. See the WARNING on the front cover. Read and follow the coating and solvent manufacturer’s safety precautions and warnings, including information regarding protective clothing, eyewear, and respirators.
Operation 6. Open the mixer manifold (N) and trigger the dispense valve (S). Startup WARNING 7. Set the air pressure to the feed pumps at 88 psi (0.6 MPa, 6 bar) or 25% of proportional pressure at the fluid outlets, whichever is less. Use the gauges (J1) to monitor this pressure. Higher pressures may prevent the proportioning pump inlet ball checks from setting properly.
Operation NOTE: Since this is a fixed ratio system, you typically do not have to check the mix ratio. 10. While observing the pump outlet gauges (J2), adjust the resin and hardener drain valves (P1,P2) until the gauges show your normal operating pressure. If the mixed fluid does not cure or harden properly, check the ratio of resin to hardener. NOTE: The pressure must be within 20% of the original spraying pressure to get a usable test. Checking the Mix Ratio 1.
Shutdown and Care of the System Pressure Relief Procedure WARNING INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury.
Troubleshooting WARNING WARNING To reduce the risk of serious bodily injury, always follow the Pressure Relief Procedure on page 21 whenever you shut off the pump, when checking or servicing any part of the dispensing system, when installing, cleaning or changing fluid tips, and whenever you stop dispensing. This chart uses the proportioner gauges to determine pump malfunctions. Faulty manifold check valves can mask pump cylinder problems. Always keep these valves operating properly.
Troubleshooting Problem System won’t run or stops while running. Solution Air pressure or volume too low. Increase, check air compressor. Closed or restricted air line or air valve. Open or clean as required. Fluid valves closed. Open fluid valves. Clogged fluid hose. Replace fluid hose. Air motor worn or damaged. Service air motor. See instructions in separate manual 306982. Displacement pump stuck. Service pump. See instructions in separate manual 307944 or 684004.
Service – Displacement Pump Removal and Replacement 33 Stop the pump at the bottom of its stroke. HARD RES Thoroughly flush the system with a solvent which is compatible to the fluid being pumped, then follow the Pressure Relief Procedure on page 21. The Flushing procedure is on page 17. CAUTION If you are changing to a different type of fluid, completely clean all of the equipment and hoses, making sure that no fluid remains in any part of the system. 125 308224 RES 24 HARD 2.
Service – Displacement Pump Disassembly 1. Remove the locknuts (113) from the top of the yoke (114) of the two outer displacement rods. See Fig. 22. Unscrew the outer locknuts (122) from the top of the tie plate (123) on the two displacement pumps. Use a screwdriver and hammer to loosen. NOTE: The tie rods (111) shown in Fig. 22 are removed from the tie plate (121) for clarity only and do not require removal. 2. Remove the two outer pumps from the tie plate.
Parts – Bare, Two Pumps Models 231643–231646 101 113 1 102 114 103 111 3 104 3 115 105 122 106 107 121 108 107 2 116 109 105 110 1 112 26 1 Torque to 53–67 ft-lb (72–91 NSm) 2 Apply anaerobic sealant and torque to 100–200 ft-lb (135–270 NSm) 3 Torque to 14–26 ft-lb (19–35 NSm) 4 Label 308224 4 118 4 HARD 120 RES 119 117 02903
Parts – Bare, Two Pumps Models 231643–231646 Ref. No. Part No. 101 207352 102 168418 103 100018 104 100017 105 100101 106 107 108 109 178471 100133 100307 168453 110 168454 111 168455 Description Qty. PRESIDENT AIR MOTOR see manual 306982 PLATE, pump adapter LOCKWASHER, 1/2 in. SCREW, hex cap head, 1/2–13 unc (2a) x 1-1/2 in. SCREW, hex cap head, 3/8–16 unc (2a) x 1.0 in. PLATE, mounting LOCKWASHER; 3/8 in. NUT, hex; 3/8–16 unc (2b) NUT, shoulder, 1-1/8–18 unef (2b) PUMP CONNECTING ROD TIE ROD; 8.
Parts – Bare, Three Pumps Models 231657, 231658, and 231663 101 3 102 113 103 114 104 111 105 106 122 108 123 107 122 109 105 110 112 1 116 121 117 RES HARD RES 120 118 4 117 4 124 125 124 119 1 Torque to 53–67 ft-lb (72–91 NSm) 2 Apply anaerobic sealant and torque to 100–200 ft-lb (135–270 NSm) 3 Torque to 14–26 ft-lb (19–35 NSm) 4 Label 5 Apply stainless steel pipe sealant to all threaded connections.
Parts – Bare, Three Pumps Models 231657, 231658, and 231663 Ref. No. Part No. 101 207352 102 168418 103 100018 104 100017 105 100101 106 107 108 109 178471 100133 100307 168453 110 168454 111 168455 112 101946 113 101926 Description PRESIDENT AIR MOTOR see manual 306982 PLATE, pump adapter LOCKWASHER, 1/2 in. SCREW, hex cap head, 1/2–13 unc (2a) x 1-1/2 in. SCREW, hex cap head, 3/8–16 unc (2a) x 1.0 PLATE, mounting LOCKWASHER; 3/8 in.
Parts – Wall Mount, Two Pumps Models 231593 and 231595 1 Apply stainless steel pipe sealant to all threaded connections except at swivels.
Parts – Wall Mount, Two Pumps Models 231593 and 231595 Ref. No. Part No. 1 see table 2 100960 3 161262 4 5 100840 206197 6 7 8 113269 158491 157416 9 159239 10 11 12 13 236061 188596 188975 102814 14 217378 15 157676 16 155699 17 161037 18 19 20 21 22 see table 159239 111591 100016 100021 23 215626 24 156823 Description Qty.
Parts – Wall Mount, Three Pumps Models 231607 and 231613 Apply stainless steel pipe sealant to all threaded connections except at swivels 1 2 Included with bare pump 3 11,12 2 5 1 4 19 13 9 6 2 7 10 8 2 14 1 18 17 1 16 22 1 15 21 20 42 38 23 11, 28 1 30 40 29 1 30 1 24 25 1 41 26 37 1 31 1 26 1 27 39 36 37 35 1 34 33 41 32 308224 1 1 02906A
Parts – Wall Mount, Three Pumps Models 231607 and 231613 Ref. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Part No. Description Qty. see table BARE PROPORTIONAL PUMP see parts on page 29 1 100960 PRESSURE GAUGE, 0–2000 psi (14 MPa, 140 bar) 1 161262 SWIVEL UNION, 90_, 1/4–18 npt(f) x 1/2 npt 1 100840 ELBOW, street, 1/4–18 npt (m x f) 1 206197 AIR REGULATOR, 300 psi (2.
Parts – Stand Mount, Two Pumps Model 231618 1 1 2 Apply anaerobic sealant and torque to 10–15 ft-lb (14–20 NSm) See parts on pages 36 and 37 50 53 51 1 52 2 38j 54 51 50 55 02907A 34 308224
Parts – Stand Mount, Two Pumps Models 231618 Ref. No. Part No. 1 231593 50 51 52 53 100321 100018 217297 100679 54 55 178473 168422 Description WALL MOUNT PUMP see parts on page 31 NUT, hex, 1/2–13 unc LOCKWASHER, 1/2 in. LEG, frame SCREW, hex cap head, 1/2–13 unc (2a) x 3–1/2 in. BRACE, frame CAP, square tube Qty.
Parts– Stand Mount, Three Pumps Models 231632 and 231638 1 1 Apply anaerobic sealant and torque to 10–15 ft-lb (14–20 NSm) 50 53 51 1 52 38a 38b 38e 38c 38d 53 1 38j 54 38f 38g 38h 51 50 55 02908A 36 308224
Parts – Stand Mount, Three Pumps Models 231632 and 231638 Ref. No. 1 50 51 52 53 54 55 Part No. Description Ref. No. 1 Qty. see table WALL MOUNT PUMP see parts on page 33 100321 NUT, hex, 1/2–13 unc 100018 LOCKWASHER, 1/2 in. 217297 LEG, frame 100679 SCREW, hex cap head, 1/2–13 unc (2a) x 3-1/2 in. 178473 BRACE, frame 168422 CAP, square tube 1 6 6 2 Model Wall Pump 231632 231607 231638 231613 6 1 6 Ref No. 38 Drain Valve Kit Supplied with the Wall Mount units and Stand Mount units Ref. No.
Accessories Parts for Installing Optional Heaters Viscon HP Fluid Heaters The following components are recommended to install the heaters as instructed on page 13. Two displacement pump models need Items 201 to 204. Three displacement pump models need Items 201 to 205 and an additional resin and hardener hose of an appropriate length. Style A Ref. No. Model 245863, 240 Volt, Stainless Steel Part No. 201 — 202 155494 203 161037 204 235905 205 217378 Description Qty.
Accessories Parts for Installing Optional Solvent Pump Ref. No. Part No. 301 151519 302 303 304 305 306 OR 307 308 309 310 311 312 313 314 315 316 Description Ref 5 301 302,303 Qty. NIPPLE, reducing, 1/4–19 nptm x 1/8–27 nptm 111913 COUPLING, hose, 1/4–18 npsm, w/spring guard, stainless steel 061132 HOSE, nylon 1/4 in. ID x 36 in.
Accessories Air Control Accessories Fluid Control Accessories Bleed-Type Master Air Valve Fluid Filter 300 psi (2.1 MPa, 21 bar) Maximum Working Pressure 5000 psi (35 MPa, 350 bar) Maximum Working Pressure Relieves air trapped in the air line between the pump air inlet and this valve when closed. 60 mesh (250 micron) screen.
Notes 308224 41
Dimensions Mounting Hole Layout for Air Motor 7 2 1 3 1 2 3 2 6 2 3 3 0288 4A 5 4 1 14–3/4 in. (375 mm) 5 30–1/4 in. (768 mm) 2 32–3/4 in. (832 mm) 6 11 in. (279 mm) 3 28–1/4 in. (718 mm) 7 12–1/2 in. (318 mm) 4 17–3/4 in. (451 mm) 42 308224 4 1 0.438 in. (11.12 mm) diameter 2 3.712 in. (92.28 mm) 3 7.424 in. (188.66 mm) 4 9.75 in. (247.
Technical Data Pumps Air operating range Air consumption 40–100 psi (0.3–0.7 MPa, 3–7 bar) See example below Fluid inlet size 3/4 npt Fluid outlet size 3/8 npt Air inlet size 3/4 npt Maximum fluid outlet pressure Maximum fluid inlet pressure Wetted parts 3000 psi (21 MPa, 210 bar) 250 psi (1.7 MPa, 17 bar) Stainless steel, Tungsten Carbide, Chrome plating, Carbon steel, PTFE, Ultra-high molecular weight polyethylene Air Consumption Example: When the air pressure to the pump is 60 psi (0.
Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.