308224 43
Technical Data
Pumps
Air operating range
40–100 psi (0.3–0.7 MPa, 3–7 bar)
Air consumption See example below
Fluid inlet size 3/4 npt
Fluid outlet size 3/8 npt
Air inlet size 3/4 npt
Maximum fluid outlet pressure 3000 psi (21 MPa, 210 bar)
Maximum fluid inlet pressure 250 psi (1.7 MPa, 17 bar)
Wetted parts Stainless steel, Tungsten Carbide, Chrome plating,
Carbon steel, PTFE, Ultra-high molecular weight
polyethylene
Air Consumption Example:
When the air pressure to the pump is 60 psi (0.4 MPa, 4 bar) and you are dispensing 1 gal. (3.8 liter) of mixed fluid
per minute, air volume used, in cfm, will be about the same as the larger pressure ratio figure of your pump. See
page 4 for pressure ratios of pumps.
Manifold assemblies
Manifold outlets 3/8 npt
Hoses
3/8 in. ID, PTFE, cpld 3/8 npt(m)
4000 psi (28 MPa, 276 bar) maximum working pressure
3/8 in. ID, Nylon, cpld 3/8 npt(m)
3000 psi (21 MPa, 210 bar) maximum working pressure
Automatic pressure relief valves wetted parts 303 stainless steel,Tungsten carbide, fluoroelastomer
Sound
Sound pressure levels (dBa)
(Input air pressures at 15 cycles/min.)
73.6 dB(A) at 40 psi (0.3 MPa, 2.8 bar)
78.3 dB(A) at 70 psi (0.5 MPa, 4.8 bar)
80.9 dB(A) at 100 psi (0.7 MPa, 7 bar)
Sound power levels (dBa)
(Input air pressures at 15 cycles/min.)
87.4 dB(A) at 40 psi (0.3 MPa, 2.8 bar)
92.1 dB(A) at 70 psi (0.5 MPa, 4.8 bar)
94.6 dB(A) at 100 psi (0.7 MPa, 7 bar)