Instructions – Parts List Parts 55 GALLON (200 LITER) DRUM SIZE 239857 Supply Module 308769D Includes elevator, stainless steel drum cover, and back-geared agitator 100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure This module fits the following pump modules: Part No. 232078 SST 3:1 President Module Part No. 232079 CST 3:1 President Module Part No. 232081 SST 3:1 President Module Part No. 232080 SST Husky 1040 Module Part No. 232082 SST Husky 1040 Module Read warnings and instructions.
Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding on page 8. D If there is any static sparking or you feel an electric shock while using this equipment, stop spraying immediately. Do not use the equipment until you identify and correct the problem.
WARNING PRESSURIZED EQUIPMENT HAZARD Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury. D Do not point the gun at anyone or at any part of the body. D Do not stop or deflect leaks with your hand, body, glove or rag. D Follow the Pressure Relief Procedure on page 10 whenever you: are instructed to relieve pressure; stop spraying; clean, check, or service the equipment; and install or clean the spray tip.
Installation WARNING FIRE AND EXPLOSION HAZARD Always maintain a minimum of 1 in. clearance between rotating agitator parts and container to prevent sparks from contact. General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Accessories, available from your Graco distributor. If you supply your own accessories, be sure they are adequately sized and pressure-rated for your system.
Installation Installing the 239857 Supply Module NOTE: Refer to Fig. 1 and to the Dimension drawing on page 14 and the Mounting Hole Layout on page 15. 1. Ensure that there is at least 9 ft (2.8 m) overhead clearance for the elevator (150) when fully raised. WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 10. 2. Remove and discard the existing suction tube at the end of suction hose (H). 3.
Installation B A Detail of Air Controls C K 2 J 159 F 4 G 105 150 108 1 101 E 102 114 Supply Module Shown with 3:1 President Pump Module H 109 3 1 Ensure that there is 9 ft (2.8 m) overhead clearance for the elevator when fully raised. 2 Mount the pump module so the top of the bracket is 4 to 5 ft (1.2 to 1.5 m) above the floor. 3 4 The suction hose is 6 ft (1.8 m) long. Do not stretch the hose tight; let it hang as shown, to assist fluid flow into the pump.
Installation Grounding WARNING Z FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 3. Y Fig. 2 1. Pump: refer to the grounding instructions in your separate pump manual. 2. Air and fluid hoses: use only electrically conductive hoses. TI1052 6. Suction hose: attach the hose ground wire to the ground lug on the agitator. See Fig. 2.
Notes 308769 9
Operation Pressure Relief Procedure WARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. To reduce the risk of an injury from accidental spray from the gun, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: D D D D are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray nozzle. 1.
Operation 150 105 124 M L P 114 D 102 125 7688B Fig.
Parts Part No.
Parts Part No. 239857, Series A, Supply Module Ref. No. 101 Description SWIVEL; sst; 3/4 npt (m x f) Part No. 112268 Qty 1 102 AGITATOR, back-geared; see manual 308609 238157 1 103 BUSHING; sst; 1” npt(m) x 3/4 npt(f) 502851 1 104 ELBOW, 90_; sst; 1” npt (fbe) 500251 1 105 HOSE, air; nylon; 1/4 in. (6 mm) ID; 1/4 npt (mbe); 50 ft (15.
Technical Data Category Data Maximum air input pressure 100 psi (0.7 MPa, 7 bar) Weight approximately 100 lb (45 kg) Wetted parts Back-Geared Agitator: See agitator manual 308609. Drum Cover: Stainless Steel Fluid Hoses: Nylon Dimensions 1 Ensure that there is 9 ft (2.8 m) overhead clearance for the elevator when fully raised.
Mounting Hole Layout 5.5 in. (140 mm) 8.88 in. (225.9 mm) 0.56 in. (14.
Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.