Parts INSTRUCTIONS-PARTS LIST This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308968 Rev. C First choice when quality counts.t INSTRUCTIONS Part No. 233021 Part No. 617418 (.1 to 4.0 GPM) (.04 to 15.0 L/Min) (.1 to 11.0 GPM) (.04 to 41.6 L/Min) Fluid Flow Meter 6000psi (41 MPa, 408 bar) Maximum Fluid Working Pressure Refer to page 2 for Table of Contents TI1003 GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 ECOPYRIGHT 2000, GRACO INC. Graco Inc.
Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unpacking and Repacking . . . . . . . . . . . . . . . . . . . . . . . Unpacking the Product . . . . . . . . . . . . . . . . . . . . . . Repacking the Product . . . . . . . . . . . . . . . . . . . . . . Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting . . . . . . . . . .
WARNING INJECTION HAZARD Spray from the applicator, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. D Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medical attention. D Do not stop or deflect fluid leaks with your hand, body, glove, or rag.
WARNING TOXIC FLUID HAZARD Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, swallowed, or inhaled. D Provide fresh air ventilation to avoid the buildup of vapors from the fluid being dispensed. D Know the specific hazards of the fluid you are using. D Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.
Unpacking and Repacking Unpacking the Fluid Flow Meter Repacking the Product The fluid flow meter was carefully packaged for shipment by Graco. When the package arrives, perform the following procedure to unpack the unit: When the fluid flow meter requires service, it is the purchaser’s responsibility to have the unit repaired. As an option, the purchaser can have the unit repaired by an authorized Graco distributor. For additional information, read the following subsections. 1.
Installation WARNING FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD To reduce the risk of fire, explosion, or electric shock: CAUTION The use of PTFE tape or pipe seal on fluid fittings upstream of this meter should be avoided if possible. Contaminants from sealing material may damage the meter. D All electrical equipment must only be installed by a qualified electrician. D Install a 100 mesh fluid filter upstream of the flow meter.
Installation Wire Diagram Grounding WARNING 5 FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD Proper electrical grounding of your system is essential. For your safety, read the warning section, FIRE, EXPLOSION, OR ELECTRIC SHOCK HAZARD, on page 3. 1 4 3 2 1. Ground the flow meter by connecting a grounded cable to the sensor.
Operation Pressure Relief Procedure WARNING INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: D are instructed to relieve the pressure, D stop spraying, D check or service any of the system equipment. 1.
Troubleshooting NOTE: The sensor is not a serviceable part. Replace it if it is malfunctioning. Problem Cause No flow volume displayed at mon- Flow volume is too low to measure itoring unit Fluid is not flowing Solution Increase flow volume. Fluid is not flowing See Problem: Fluid is not flowing, below. Damaged cable Replace cable. Improper input voltage to sensor Make sure input power is 7–29 Vdc. Damaged sensor Replace sensor if it is malfunctioning.
Notes 10 308968
Maintenance WARNING FIRE AND EXPLOSION HAZARD If the meter is not installed in an intrinsically safe installation, make sure the power is off or the electronic sensor is disconnected before wiping the outside of the meter clean with a cloth dampened in a compatible solvent or flushing the meter. CAUTION Do not immerse the meter in solvent with the electronic sensor installed. Solvent could damage the electrical components. Air purge is not recommended for any gear-type flow meter.
Maintenance Disassembly WARNING INJECTION HAZARD To reduce the risk of an injection injury or other serious injury, follow the Pressure Relief Procedure on page 8 whenever you are instructed to relieve pressure. 7. Remove and inspect the helical gears (80 and 90), the sleeve bearing (120) and the sleeve (110) by lifting the gears straight out. 8. Check that the ball bearings (100) do not fall out. 9. Unscrew the housing bolts (10) and remove the inlet housing (50). Inspection 1. Inspect the gears 2.
Parts Model 617418, Fluid Flow Meter Ref No. 10 20 30 40 50 60 70 80 Part No. Description * * * * * * * * BOLT, inlet housing BOLT, sensor housing O–RING PIN, locating HOUSING, inlet HOUSING, sensor HOUSING, gear GEAR, large helical Qty . 6 6 2 1 1 1 1 1 ÁÁÁÁ ÁÁÁ ÁÁÁÁÁÁÁÁÁÁ ÁÁÁ ÁÁÁÁ ÁÁÁ ÁÁÁÁÁÁÁÁÁÁ ÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁ ÁÁÁ ÁÁÁÁ ÁÁÁ ÁÁÁÁÁÁÁÁÁÁ ÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁ ÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁ ÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁ ÁÁÁ Ref No. 90 100 110 120 130 140 150 Part No.
Accessories Use Only Genuine Graco Parts and Accessories Fluid Filter C58997 Electrical Cables 5000 psi (350 bar) Maximum Working Pressure With stainless steel bowl and polyethylene support For connecting to sensor 30 Mesh Filter Screen 515222 Recommended for use with Fluid Filter C58997. Filter Bank C59547 5000 psi (350 bar) Maximum Working Pressure P–Flo Cable 617707 60 ft (18.3 m) cable with terminal ends for connecting to Sensor and Precision Flo Control Boxes. Cable 196842 24 ft (7.
Technical Data Mechanical Specifications Flow Range Mode l 617418 . . . . . . . . . . . . . . . . . 0.1–11 gal/min (0.4–41.6 L/min) Model 233021 . . . . . . . . . . . . . . . . . 0.1–4.0 gal/min (0.4–15.0 L/min) Flow Meter Connector Size Mode l 617418 . . . . . . . . . . . . . . . 13,300 per Gallon (3,500 per Liter) Model 233021 . . . . . . . . . . . . . . . 34,700 per Gallon (9,166 per Liter) Maximum Operating Pressure Mode l 617418 . . . . . . . . . . . . . . . . . . . . . . 6000 PSI (40.
Related Publications Product Form# Mastic Regulators Volume Verification and Batch Control Meter PrecisionFlo Control Module PrecisionFlo Plus Controller 307517 308967 310531 310558 16 308968
Notes 308968 17
Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.