Instructions - Parts Helical Gear Fluid Flow Meters 309834R EN Positive displacement helical gear flow meters designed for higher flow rates and higher viscosity materials. For professional use only. Not approved for use in European explosive atmosphere locations. 6000 psi (41 MPa, 410 bar) Maximum Fluid Working Pressure See page 2 for a list of models. Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.
Models Contents Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Dust and Foreign Matter . . . . . . . . . . . . . . . . . . . 5 Installing the Flow Meter . . . . . . . . . . . . . . . . . . . 5 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Operation . . . . . . . . . . . . . . . . . . . . . . . .
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
Warnings WARNING SKIN INJECTION HAZARD Spray from the gun, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. • Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgical treatment. • Do not stop or deflect fluid leaks with you hand, body, glove, or rag.
Installation Installation Installing the Flow Meter • Flow volume can only be measured at the location where the flow meter is installed. Dust and Foreign Matter • Do not use more than 200 ft. (61 m) of cable. Avoid having dust or foreign matter enter the flow meter by taking the following precautions: • Refer to FIG. 1 to locate and install the flow meter, connectors, and fluid shutoff valves. Install a check valve to prevent backflow.
Installation Grounding 2. Never use the flow meter with an electrostatic gun isolation stand. Sensor Connector Pin-out 1. Always ground the fluid supply unit, using one of the following options: 4 a. Mount the meter to a grounded conductive surface, or b. Connect the conductive fluid hose to the meter inlet and outlet. c. Connect a ground wire to the meter’s M6 mounting holes.
Operation Operation Flow Meter Verification Pressure Relief Procedure 1. Turn off the fluid supply to the meter. 2. Shut off all electrical power to the fluid system. 3. Follow the Pressure Relief Procedure for your fluid system dispensing device. Flow Meter Function This is a positive displacement, gear flow meter. The gear flow meter is highly accurate, even with low flow rates. The fluid flowing through the meter rotates the gears. The gear position is monitored by a sensor device.
Troubleshooting Troubleshooting The sensor is not a serviceable part. Replace it if it is malfunctioning. Problem Cause No flow volume displayed at monitor- Flow volume is too low to measure ing unit Fluid is not flowing Fluid is not flowing Damaged cable Improper input voltage to sensor Damaged sensor Clogs in fluid line or in meter Gears worn or damaged 8 Solution Increase flow volume. See Problem: Fluid is not flowing, below. Replace cable. Make sure input power is 10-30 Vdc.
Maintenance Maintenance 4. Follow the Pressure Relief Procedure, then disconnect the fluid line from the solvent supply unit. 5. Reconnect the fluid line to the fluid supply. CAUTION Do not immerse the meter in solvent with the electronic sensor installed. Solvent could damage the electrical components. Air purge is not recommended for any gear-type flow meter. Air purges do not provide the lubrication the meter gears require.
Maintenance 5. Hold the end housing (1) and gently alternately tap on the two screws (2) with a hammer to separate the middle housing (11). 7. Insert the 3-tooth helical gear (8) into the gear bearing (5), making sure the two helical gears mesh with each other. 6. Remove the last two screws (2) and carefully separate the end (1) and middle housings (11) completely. 8. Line up the holes in the middle housing (11) with the helical gears, and carefully slide the housing over the gears. 7.
Parts Parts Model 246190, HG6000 Meter 19 23 18 2 17 15 5 3 6 21 13 7a 7e 7b 24 2 7d 7f 7c 22 16 7 1 20 17 9 5 15 6 3 7e 7e 16 8 r_246190_309834_3r 5 4 3 6 3 1 2 1 Ref.
Parts Model 280560, HG6000 Meter 19 23 18 2 17 15 5 3 6 21 13 7a 2 7e 7b 24 7d 7f 7c 22 16 7 20 1 17 9 5 15 6 3 7e 7e 8 16 r_246190_309834_3r 5 4 3 6 3 1 2 1 Ref.
Parts Part No. 15V820 Helical Gear Fluid Flow Meter Assembly (uses sensor approved for use on ProMix 2KS Control Platform) 110 101 102 105 103 102 104 106 109 107 107 TI17224a 108 Ref. Part Description Qty. 1 101 280560 METER, HG6000; see page 12 2 102 15M861 REDUCER, pipe; 3/4 npt(m) x 1/4 npt(f) 1 103 166846 ADAPTER; 1/4 npt x 1/4 npsm 1 104 205099 HOSE, fluid, high pressure; ptfe; 2.5 ft (0.76 m); 1/4 npsm(fbe) 1 105 501867 VALVE, check; 1/4 npt(mbe) 309834R Ref.
Parts Model 246340, HG6000HT Meter and Model 24R174, HG6000HT-FM Meter 29 28 35 27 39 18 2 17 40 4 6 7a 33 15 36 26 13 25 7b 2 41 7d 7f 7c 42 22 33 16 5 7a 7e 32 34 20 3 8 24 7e 31 6 5 4 3 4 30 1 23 3 2 1 1 20 3 Torque to 350 +/- 15 in-lb (39.5 +/-1.7 N•m) 2 Torque to 45 +/- 15 in-lb (5.09 +/- 1.7 N•m) 3 Apply thermal lubricant (45) 4 After ball (6) is placed into bearings, apply grease (52) into bearing area.
Parts Model 246340, HG6000HT Meter and Model 24R174, HG6000HT-FM Meter Ref. 1 2 3 4† 5† 6† 7* 7** Part 117535 246594 101680 234052 24R205 7a 7b 7c 7d 7e 7f 8* 234053 8** 24R690 13* 15† 16*† 17† 18† 19 20 21 22 116614 15B774 15C336 23 24 25 26 27 28 29 C32255 C34043 101674 112144 C34040 189930 290228 117541 309834R Description Qty.
Parts Model 246652, HG6000HR Meter and Model 24P688, HG6000HR-FM Meter 19 23 18 2 17 3 6 21 13 7a 2 7e 7b 24 15 5 7d 16 7f 22 7c 7 20 1 9 5 15 16 17 7e 7e 6 3 8 r_246652_309834_1l 5 4 3 6 3 1 2 Ref. 1 2 3 4† 5† 6† 7* 7** Part 117535 246594 101680 246686 24P689 7a 7b 7c 7d 7e 7f 8* 234053 8** 24P690 16 1 Torque to 350 +/- 15 in-lb (39.5 +/- 1.7 N•m) 2 Torque to 42 +/- 15 in-lb (4.75 +/- 1.
Dimensions Dimensions Flow Meter Port Size 3.0 in. 76.2 mm 5.6 in. 142.2 mm 6.1 in. 154.9 mm 3/4 - 14 npt(f) Outlet 3/4 - 14 npt(f) Inlet Flow Meter Mounting Holes 2.1 in. (TOP VIEW) (53.3 mm) Flow Meter Mounting Holes (BOTTOM VIEW) 1.0 in. (25.4 mm) TI9122A Weight 12 lbs (5.44 kg) M6 x 1 309834R M4 x 7 x .
Technical Data Technical Data Category Data Maximum Working Fluid Pressure 6000 psi (41 MPa, 410 bar) Flow Range Models 246190, 246340, 280560, 15V820, and 24R174: 0.013 to 6.0 gpm (50 to 22,712 cc/min) Models 246652 and 24P688: 0.007 to 2.0 gpm (25 to 7571 cc/min.
Accessories Pressure Drop vs. Flow Rate in 1000 cps Oil 80 Pressure Drop (PSI) 70 60 50 40 30 20 10 0 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 Flow Rate (GPM) Accessories Use Only Genuine Graco Parts and Accessories Fluid Filter C58997 (30 mesh) 5000 psi (350 bar) Maximum Working Pressure High Resolution Meter Sensor Replacement Kit 246786 Recommended for use with Fluid Filter C58997. The sensor update has been made to meters 246190 Series D, 246340 Series D, 246652 Series C, and newer.
Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.