User's Manual
Installation
4 310652K
Wall-mount
1. Fasten the wall-mount bracket (part no. 249568) to
the wall using screws long enough to provide secure
support. See F
IG. 3.
2. Observe the flow-direction arrows on the top of the
filter assembly. See F
IG. 5. Position the filter assem-
bly correctly and secure the assembly to the bracket
using four screws (10) for models 248418 and
248421 or three screws (107) for models 248417
and 248419.
Pump-mount
1. Attach the pump-mount bracket (part no. 249565) to
the base of the pump. See F
IG. 4. The method of
attachment will vary by pump. The Fire-Ball 425 6:1
and 425 10:1 pumps use machine screws to mount
the bracket into pre-tapped holes tn the pump base.
The 425 3:1 is not compatible with the pump mount
bracket. The Fire-Ball 225 and 300 series pump
bases are not tapped. You will need to use the
machine screws and lock-nuts provided with bracket
kit 249565.
2. Observe the flow-direction arrows on the top of the
filter assembly. See F
IG. 5. Position the filter assem-
bly correctly and secure the assembly to the bracket
using four screws (10) for models 248418 and
248421 or three screws (107) for models 248417
and 248419.
CleanLine 900
1. Install barbed fitting (9) and pressure relief tube (12)
as shown in F
IG. 6. Apply thread sealant to threads
of barbed fitting (9).
2. Route the tube (12) back to bulk tank or to used oil
container.
F
IG. 3
Part No. 249568
Wall Mount
F
IG. 4
F
IG. 5
Part No. 249565
Pump Mount
CleanLine 1800 Filter
Models 248417 and 248419
CleanLine 900 Filter
Models 248418 and 248421