User's Manual
Operation
6 310652K
4. Ensure the main fluid outlet valve at the pump is
closed.
5. Place dispense end of hose into a waste oil con-
tainer. Secure the hose so it will not come out during
flushing.
6. Slowly open the main fluid outlet valve at the pump.
At the same time, gradually increase the air pres-
sure to the pump until there is good flow through the
hose.
7. Dispense fluid continuously at 2 gpm or more for the
length of time determined by the table information.
In an existing fluid line, the flushed oil can be
returned to the bulk tank and reused. In a newly
installed line, the flushed oil should be not be
reused.
8. Repeat this procedure for each dispense location
and each service fluid in the system.
9. After service fluids have been flushed install
meter(s).
10. The system is now ready for use.
CleanLine Filter Cartridge
Replacement
The CleanLine Filter cartridge should be replaced at
least once a year or any time you notice a reduced flow
rate or other signs of degraded performance. To replace
the CleanLine Filter, perform the following steps:
CleanLine 900 Filter (models 248418 and 248421)
1. Relieve pressure (see Relieve Pressure on page 5).
2. Close both ball valves (6).
3. Place a waste container below the filter to catch the
oil in the filter.
4. Unscrew the filter (5).
5. Apply oil to the new filter seal.
6. Tighten new filter 1/10 turn after filter contacts base.
7. Open both ball valves (6).
8. Turn system pressure back on.
CleanLine 1800 Filter (models 248417 and 248419)
1. Relieve pressure (see Relieve Pressure on page 5).
2. Close both ball valves (101).
3. Place a waste oil container below the filter to catch
the oil in the housing (104) and filter cartridge (103).
4. Unscrew the housing (104).
5. Pull the filter cartridge (103) straight down.
6. Apply grease to the o-ring inside the replacement
cartridge (103).
7. Firmly push the replacement cartridge (103) straight
up, onto the nipple inside the manifold (102).
8. Replace the housing (104) and torque to 15 ft. lbs.
9. Open both ball valves (101).
10. Turn system pressure back on.
It is all right to flush with mineral spirits, kerosene
and other petroleum-based fluids with the Clean-
Line Filter installed.
WARNING
Follow Relieve Pressure procedure before replacing
CleanLine Filter cartridge. Read warnings on page 2.
Replacing the filter cartridge allows air into the sys-
tem. Spitting will occur during dispense until air is
purged from the system.
Replacing the filter cartridge allows air into the sys-
tem. Spitting will occur during dispense until air is
purged from the system.