User's Manual

Service
311775E 5
Service
1. Relieve all fluid pressure from the system. See the
Warning above and your pump/sprayer manual.
NOTE: In some applications, closing outlet valve is not
required.
2. Drain housing sufficiently to access filter basket (2).
3. Remove cover by loosening the cover eye-nuts (3).
Loosen the eye-nuts in the slotted corners so the
bolts swing down. Loosen the third eye-nut so the
top cover can swing open.
4. Remove filter basket (2) and clean thoroughly.
5. Remove the filter bag (if applicable, not shown) and
throw away. (Cleaning and reusing the filter bag is
not recommended.)
6. Thoroughly clean the inlet (A) to avoid interference
with cover seal or fluid flow.
7. Remove basket seal (if applicable) and inspect.
Replace if necessary.
8. Install clean filter basket and filter bag (if applica-
ble). Put basket (2) into filter housing. Make sure the
basket flange is seated firmly on top of the basket
collar. Put bag into the bag basket. Be sure the filter
bag ring is seated firmly on top of the basket flange.
For best results, be sure the filter bag extends to the
bottom of the basket.
9. Make sure that the cover gasket groove is clean and
free of debris. Replace cover seal gasket (1).
NOTE: If the cover has ever been tightened down, the
cover seal gasket must be replaced.
10. Close cover and alternately tighten the three clamp
assemblies (by small increments) to a recom-
mended torque of 30-45 ft-lb (40-60 N•m).
PRESSURIZED EQUIPMENT HAZARD
Before removing, cleaning, or servicing the filter,
close the inlet and outlet ball valves and open the
fluid drain valve to relieve pressure.
1
2
3
A
B
ti10098a