Instructions - Parts Feed Pump and Agitator Kits 312769D EN Supplies viscous materials from drums or 20 gallon hoppers to XM™ and XP70 plural-component sprayers. Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. See page 5 for model information, including maximum working pressure and approvals.
Related Manuals Contents Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Feed Kit Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Install Feed Pump . . . . . . . . . . . . . . . . . . . . . . . . 6 Install Agitator . . . . . . . . . . . . . .
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable. WARNING WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode.
Warnings WARNING WARNING MOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
Feed Kit Models Feed Kit Models All kits fit drums or 20 gallon hoppers. Most packages include all air and fluid fittings and hoses. Approvals are only for the pumps or agitator and not for the entire package. Complete Package (fluid and air) 256274 Agitator Kit with air connection 100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure T2 2:1 Ratio Transfer Pump Kit 180 psi (1.2 MPa, 12 bar) 405 psi (2.8 MPa, 28 bar) 256276 Monark® 5:1 Ratio Pump Kit 180 psi (1.2 MPa, 12 bar) 900 psi (6.
Installation Installation Grounding Install Feed Pump The equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up. Connect grounding wire to grounding screw (Z) on back of XM sprayer or any earth ground. NOTE: President 10:1 feed pump kit 256433 is only recommended for drum feed applications and highly viscous materials. Do not install in hoppers as this will result in pulsation at the gun.
Installation d. Adjust pump so there is at least 2.5 in. (64 mm) between the pump shoulder and the top of the bung adapter (B). e. Orient the two spacer halves on the pump shaft so spacer contacts the pump shoulder. f. Install Agitator NOTICE Keep agitator tightly mounted to hopper to prevent damage to threads from vibration. Ensure that there is no interference between base of hopper and shaft of agitator. Tighten the spacer using provided hardware. g.
Installation Connect Air Lines 6. If only using an agitator: a. Connect air line (55) and coupler (56) into fitting (54). Shown in 20 gallon hopper. Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing or moving parts. A 52 53 B 54 H 1. 5:1 Monark pump only: Install air regulator kit (22). 56 2. 10:1 President pump only: Remove 3/8 npt nipple from air regulator kit (22).
Operation b. For T2 2:1 pump only: Interconnect tee fitting (2) and quick disconnect fitting (1b) on pump with air hose (5). 256275 2:1 Pump Kit Shown Shown in 20 gallon hopper. C 1b 5 2 FIG. 3: XP70 Sprayer Flush Before Using Equipment 55 5 r_256275_312769_3A 8. Remove one cap (C) from the air manifold (M) on the sprayer and the connect air line from the agitator or pump. The equipment was tested with lightweight oil, which is left in the fluid passages to protect parts.
Parts Parts Feed Pump Kits Monark 5:1 Pump Kit 256276 T2 2:1 Pump Kit 256275 1 1 22 1a 8 1b 7 8 3 7 5 23 24 3 1 2 1 3 5 1 3 1 2 1 3 1 r_256275_312769_1 r_256275_312769_7A Sprayer Pump Inlet Connection 10 1 11 Only used when agitator is used with pump. See page 12.
Parts Feed Pump Kit Parts These parts are used in the T2 2:1 Pump Kit 256275 and Monark 5:1 Pump Kit 256276. Ref. Part Description Qty. 1 * 295616 PUMP, 2:1 transfer pump; manual 1 311882; includes 1a and 1b † 218956 PUMP, 5:1 Monark, see manual 1 307044 1a* QUICK DISCONNECT FITTING 1 1b* COUPLER 1 2 104984 FITTING, tee; 1/4 npt (f) 1 3 156971 NIPPLE, short; 1/4-18 npt 3 5 212005 HOSE, coupled; 6 ft 1 7 118459 UNION, swivel, 3/4 in.
Parts Agitator Kit 256274 53 52 51 Detail A: Agitator and Feed Pump Air Fittings 54 52 2 56 3 53 57 3 54 to sprayer to feed pump 55 agitator, page 12 r_256275_312769_5 Ref. 51 52 53 Part Description Qty.
Technical Data Technical Data Maximum air input pressure Agitator Kit 256274 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T2 Feed Pump Kit 246275 . . . . . . . . . . . . . . . . . . . . . . . . Monark 5:1 Feed Pump Kit. . . . . . . . . . . . . . . . . . . . . . . . President 10:1 Ratio Pump . . . . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar) 180 psi (1.2 MPa, 12 bar) 180 psi (1.2 MPa, 12 bar) 90 psi (0.62 MPa, 6.
Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.