User's Manual

Component Identification
12 313527V
Integrated Air Control Module
D200, D200s, D60, and S20 Models
The integrated air controls include:
Main air slider valve (BA): turns air on and off to
the system. When closed, the valve relieves pres-
sure downstream.
Ram air regulator (BB): controls ram up and down
pressure and blowoff pressure.
Ram director valve (BC): controls ram direction.
Exhaust port with muffler (BD)
Air motor regulator (BE): Controls air pressure to
motor.
Air motor slider valve (BF): turns air on and off to
the air motor. When closed, the valve relieves air
trapped between it and the air motor. Push the valve
in to shutoff. Remote DataTrak: The air solenoid,
the air motor slider valve (BF), and the main air
slider valve (BA) must be open for air to flow. (See
Remote DataTrak Setup, in manual 312371)
Blowoff button (BG): turns air on and off to push
the platen out of an empty drum.
Integrated Air Line Accessories
See F
IG
. 1.
Air line drain valve (U)
Air line filter (V): removes harmful dirt and mois-
ture from compressed air supply.
Second bleed-type air valve (W): isolates air line
accessories for servicing. Locate upstream from all
other air line accessories.
Air relief valve (not visible): automatically relieves
excessive pressure.
2-Button Interlock Air Controls
D200i, D200si, and D60i Models
Units that have 2-Button Interlock controls have the fol-
lowing additional components:
2-Button Module: See manual 312374 for informa-
tion.
Roller switch (CA): shuts off air supply when it
contacts the bracket actuator. Operator must push
and hold buttons to resume ram movement.
Bracket actuator (CB): attaches to the platen lift
rod. When ram is near the top, actuator makes con-
tact with the roller switch.
F
IG
. 3. Integrated Air Control Module
BA
BB
BC
BG
BE
BF
BD
ti10438a
F
IG
. 4
F
IG
. 5
Activation
Buttons
ti10843a1
CA
CB
ti10846a