Setup Mode
36 313882C
Advanced Setup Screen 3
This screen appears only if Flush and Fill Input is set to
“Global” in Option Screen 1, page 32.
If Number of Guns is set to “2” in Configure Screen 4,
page 30, a Gun 2 column will appear in this screen.
First Purge Time (Stage 1)
Enter the first purge time (0 to 999 seconds) for compo-
nents A and B.
C First Purge Time (Stage 2)
Enter the component C first purge time (0 to 999 sec-
onds).
Total Chop Time (Stage 1)
Enter the total chop time (0 to 999 seconds) for compo-
nents A and B.
Final Purge Time (Stage 1)
Enter the final purge time (0 to 999 seconds) for compo-
nents A and B.
C Final Purge Time (Stage 2)
Enter the component C final purge time (0 to 999 sec-
onds).
Mixed Fill Time
Enter the mixed fill time (0 to 999 seconds). It refers to
the amount of material that is required to fill from the
dose valves to the applicator/gun.
Advanced Setup Screen 4
This screen appears only if K-Factor Input is set to
“Global” in Option Screen 1, page 32.
K-factor A Meter
Enter the k-factor (cc/pulse) for flow meter A. This is the
amount of material that passes through the flow meter
per pulse (electrical pulse signal).
K-factor B Meter
Enter the k-factor (cc/pulse) for flow meter B.
K-factor C Meter
Enter the k-factor (cc/pulse) for flow meter C.
K-factor Solvent Meter
This field only appears if Solvent Monitor in Configure
Screen 5, page 31, is set to “Meter.” Enter the k-factor
(cc/pulse) for the solvent flow meter.
F
IG. 34. Advanced Setup Screen 3
FIG. 35. Advanced Setup Screen 4