Setup Mode
40 313882C
Recipe Setup Screen 3
This screen appears only if Flush and Fill Input is set to
“Recipe” in Option Screen 1, page 32.
First Purge Source
Select “Air,” “Solvent,” or “3rd Flush Valve” (available
only if 3rd Flush Valve is set to “On” in Configure
Screen 3 on page 30).
Chop Type
Select “Air/Solvent” or “Air/3rd Flush Valve” (available
only if 3rd Flush Valve is set to “On” in Configure
Screen 3 on page 30). This refers to the process of mix-
ing air and solvent (or air and 3rd flush fluid) together
during the flush cycle, to help clean the lines and reduce
solvent usage.
Final Purge Source
Select “Air,” “Solvent,” or “3rd Flush Valve” (available
only if 3rd Flush Valve is set to “On” in Configure
Screen 3 on page 30.)
Air Chop Time
Enter the air chop time (0.0 to 99.9 seconds).
Solvent Chop Time/3rd Flush Valve Chop Time
Enter the solvent or 3rd flush valve chop time (0.0 to
99.9 seconds).
Recipe Setup Screen 4
This screen appears only if Flush and Fill Input is set to
“Recipe” in Option Screen 1, page 32.
If Number of Guns is set to “2” in Configure Screen 4,
page 30, a Gun 2 column will appear in this screen.
First Purge Time (Stage 1)
Enter the first purge time (0 to 999 seconds) for compo-
nents A and B.
C First Purge Time (Stage 2)
Enter the component C first purge time (0 to 999 sec-
onds).
Total Chop Time (Stage 1)
Enter the total chop time (0 to 999 seconds) for compo-
nents A and B.
Final Purge Time (Stage 1)
Enter the final purge time (0 to 999 seconds) for compo-
nents A and B.
C Final Purge Time (Stage 2)
Enter the component C final purge time (0 to 999 sec-
onds).
Mixed Material Fill Time
Enter the mixed material fill time (0 to 999 seconds). It
refers to the amount of material that is required to fill
from the dose valves to the applicator/gun.
F
IG. 40. Recipe Setup Screen 3