User's Manual

Setup Mode
313882C 41
Recipe Setup Screen 5
This screen appears only if K-Factor Input is set to “Rec-
ipe” in Option Screen 1, page 32.
K-factor A Meter
Enter the k-factor (cc/pulse) for flow meter A. This is the
amount of material that passes through the flow meter
per pulse (electrical pulse signal).
K-factor B Meter
Enter the k-factor (cc/pulse) for flow meter B.
K-factor C Meter
Enter the k-factor (cc/pulse) for flow meter C.
K-factor Solvent Meter
This field only appears if Solvent Monitor in Configure
Screen 5, page 31, is set to “Meter.” Enter the k-factor
(cc/pulse) for the solvent flow meter.
Recipe Setup Screen 6
This screen appears only if Flow Rate Monitor is set to
“On” in Option Screen 2 on page 33.
Flow Rate Monitor
Select the desired flow rate monitoring (Off, Warning, or
Alarm).
Low Flow Limit
Enter the low flow rate limit (1 to 3999 cc/min).
High Flow Limit
Enter the high flow rate limit (1 to 3999 cc/min).
Recipe Setup Screen 7
This screen appears only if Flush and Fill Input is set to
“Recipe” in Option Screen 1, page 32 and Special Out-
puts is set to 1, 2, 3, or 4 in Configure Screen 5, page
31. The I/O board has four programmable outputs.
F
IG. 42. Recipe Setup Screen 5
FIG. 43. Recipe Setup Screen 6
F
IG. 44. Recipe Screen 7