User's Manual

System Operation
46 313882C
5. Components A and B are pre-mixed in the 2KS inte-
grator, then uniformly blended in the 2KS static
mixer (SM) before flowing through the hose to the
3KS Fluid Manifold inlet.
Stage 2 (see FIG. 50, ProMix 3KS Detail)
6. Dose Valve C (DVC) opens, and fluid flows into the
3KS integrator and is aligned proportionately with
components A+B (mixed in Stage 1).
7. Flow Meter C (MC) monitors the fluid volume dis-
pensed and sends electrical pulses to the ProMix
3KS controller.
8. When the target volume is dispensed, Dose Valve C
closes.
9. Components A+B and C are pre-mixed in the 3KS
integrator, then uniformly blended in the 3KS static
mixer (SM).
NOTE: To control output from the 3KS static mixer
to the gun, install an optional fluid pressure regula-
tor.
10. Components A+B and C are alternately fed into the
2KS integrator as long as the gun is triggered.
11. If the gun is not triggered for two minutes, the sys-
tem switches to Idle mode, which closes off the mix
manifold dose valves.
12. When the gun is triggered again, the ProMix 3KS
continues the process where it left off.
NOTE: Operation can be stopped at any time by
pressing the Standby key or shutting off the
main power switch.
Table 5: Sequential Dosing Operation
Ratio = 2.0:1
Dose 1 Dose 2
Stage 1 (A:B)
Stage 2
(A+B):C Stage 1 (A:B)
Stage 2
(A+B):C
A = 2
B = 1
C = 1