User's Manual

System Operation
60 313882C
3. Adjust the solvent fluid supply pressure. Use the
lowest possible pressure to avoid splashing.
4. Remove the Fluid Station cover to access the sole-
noid valves. See F
IG. 57.
5. Purge as follows:
Single color/single catalyst/single compo-
nent C systems: Purge component A side.
Press the manual override on the Dose Valve A
solenoid valve and trigger the gun into a
grounded metal pail.
Purge component B side. Press the manual
override on the Dose Valve B solenoid valve
and trigger the gun into a grounded metal pail
until clean solvent flows from the gun.
Purge component C side. Press the manual
override on the Dose Valve C solenoid valve
and trigger the gun into a grounded metal pail
until clean solvent flows from the gun.
Repeat to thoroughly clean the fluid integrator.
Multiple color/multiple catalyst/multiple
component C systems: Select Recipe 0 and
press Enter to purge the complete system.
The color change LED blinks while Recipe 0
runs and turns solid after purge sequence is
complete.
Repeat to thoroughly clean the fluid integrator.
6. Reinstall the Fluid Station cover.
7. Shut off the solvent fluid supply.
8. Disconnect the solvent supply lines and reconnect
the component A, B, and C fluid supplies.
9. See page 50 for Start Up procedure.