User's Manual

Color Change
66 313882C
Final Purge
Select the Final Purge Source (air, solvent, or 3rd valve)
and Final Purge Time. For most applications, solvent is
selected.
The system fills the line with solvent from the dose
valves to the gun, using only the selected purge media
(usually solvent). The selected purge valve opens during
the Final Purge Time and closes when the time expires.
Final Purge C
Select the Final Purge C Source (solvent or water) and
Final Purge C Time. For most applications, solvent is
selected.
The system fills the line with solvent from the dose
valves to the gun, using only the selected purge media.
The purge C valve opens during the Final Purge C Time
and closes when the time expires.
Fill
This sequence fills the line from the dose valves to the
gun, and is also referred to as the mixed material fill.
The system begins mixing components A, B, and C until
the Fill Time expires.
Purge Active
The system turns on the Purge/Recipe Change Purge
Active output during these steps.
Fill Active
The system turns on the Recipe Change Fill Active out-
put during this step.
Table 8: ProMix 3KS Color Change Chart Reference
Starting
Recipe
Ending
Recipe
A/B/C
Change
3rd Purge
Valve Refer to Fig.
XYYesYesF
IG. 62
XYYesNoF
IG. 63
XYNoYesF
IG. 64
X Y No No F
IG. 65
XYExternalYesF
IG. 70
XYExternalNoF
IG. 71
X0n/aYesF
IG. 66
X0n/aNoF
IG. 67
0 or 61 X Yes Yes F
IG. 68
0 or 61 X Yes No FIG. 69
0 or 61 0 n/a Yes F
IG. 66
0 or 61 0 n/a No F
IG. 67