User's Manual

Alarms and Warnings
313882C 77
Alarms and Warnings
System Alarms
System alarms alert you of a problem and help prevent
off-ratio spraying. If an alarm occurs, operation stops
and the following occurs:
A red LED illuminates steadily or blinks on the Booth
Control.
Booth Control displays an alarm E-Code, E-1 to
E-31. See F
IG. 72.
Alarm sounds.
Status bar on the EasyKey Display shows the alarm
E-Code with a description (see Table 9).
System Warnings
Table 9 lists the System Warning Codes. Warnings do
not stop operation or sound an alarm. They are saved in
the date/time stamped log, which can be viewed on a
PC, using the ProMix 2KS Web Interface (see manual
313386).
To Reset Alarm and Restart
NOTE: When an alarm occurs be sure to determine the
E-Code before resetting it. See Table 9. If you forget
which E-Code occurred, use the Alarms Screens (page
23) to view the last 10 alarms, with date and time
stamps.
To reset alarms, see Table 10. Many alarms can be
cleared by simply pressing the Alarm Reset
key.
NOTICE
Do not use the fluid in the line that was dispensed off
ratio as it may not cure properly.
F
IG. 72. Booth Control
TI11614A
Display
Recipe Indicator (green)
Alarm Indicator (red)
Table 9: System Alarm/Warning Codes
Code Description Details
E-1 Communication Error Alarm Page 78
E-2 Potlife Alarm Page 78
E-3 Ratio High Alarm Page 79
E-4 Ratio Low Alarm Page 80
E-5 Overdose A/B Dose Too Short Alarm Page 81
E-6 Overdose B/A Dose Too Short Alarm Page 81
E-7 Dose Time A Alarm Page 82
E-8 Dose Time B Alarm Page 82
E-9 Mix in Setup Alarm Page 83
E-10 Remote Stop Alarm Page 83
E-11 Purge Volume Alarm Page 83
E-12 CAN Network Communication Error
Alarm
Page 84
E-13 High Flow Alarm Page 85
E-14 Low Flow Alarm Page 85
E-15 System Idle Warning Page 85
E-16 Setup Change Warning Page 85
E-17 Power On Warning Page 85
E-18 Defaults Loaded Warning Page 85
E-19 I/O Alarm Page 86
E-20 Purge Initiate Alarm Page 87
E-21 Material Fill Alarm Page 87
E-22 Tank A Low Alarm Page 88
E-23 Tank B Low Alarm Page 88
E-24 Tank S Low Alarm Page 88
E-25 Auto Dump Complete Alarm Page 88
E-26 Color/Catalyst Purge Alarm Page 88
E-27 Color/Catalyst Fill Alarm Page 88
E-29 Tank C Low Alarm Page 88
E-30 Overdose C Alarm Page 81
E-31 Dose Time C Alarm Page 82