User's Manual

Alarm Troubleshooting
313882C 85
E-13: HIGH_FLOW_ALARM or E-14: LOW_FLOW_ALARM (may also be set as Warnings)
Cause Solution
Fluid system is producing too much or too little flow. Troubleshoot fluid system for restrictions, leaks,
exhausted fluid supply, incorrect settings, etc. Increase
or decrease flow rate, as required.
E-15: SYSTEM_IDLE_WARNING
Cause Solution
Mix input is high, but the gun has not been triggered for 2
minutes.
If not painting, clear alarm and resume operation.
If painting, shut down and inspect fluid meter and air flow
switch.
E-16: SETUP_CHANGE_WARNING
Cause Solution
The system setup parameters have been changed. No action required. See Event Log available through
advanced web interface.
E-17: POWER_ON_WARNING
Cause Solution
The power to the system has been cycled. No action required. See Event Log available through
advanced web interface.
E-18: DEFAULTS_LOADED_WARNING
Cause Solution
The factory defaults have been installed on the system. No action required. See Event Log available through
advanced web interface.
Table 10. Alarm Troubleshooting