User's Manual

Schematic Diagrams
94 313882C
System Electrical Schematic
NOTE: The electrical schematic illustrates all possible wiring expansions in a ProMix 3KS system. Some compo-
nents shown are not included with all systems.
Hazardous Area
+12VDC I/S
COM
SHIELD
J10
1
2
3
1
2
3
4
5
6
J3
PWR (RED)
COM (BLACK)
SIG (WHITE)
SHIELD/GRN
PWR (RED)
COM (BLACK)
SIG (WHITE)
SHIELD/GRN
PWR (RED)
COM (BLACK)
SIG (WHITE)
SHIELD/GRN
SMART
FLUID
PANEL
CONTROL
BOARD
SMART FLUID PANEL
CONTROL BOX
FLOW METER A
FLOW METER B
1
2
3
4
5
6
J5
1
2
3
4
5
FLOW
CONTROL
BOARD
6
5
4
3
2
1
J9
GREEN
BLACK
BLACK
RED
BLACK
RED
DOSE B
DOSE A
1
2
3
4
5
6
7
8
9
10
J1
SIG
COM
SIG
COM
SIG
COM
SIG
COM
SIG
COM
AIR FLOW SWITCH 1
FO OUT
(BLU)
FO IN
(BLK)
1
2
J1
J2
3X CABLE
FLOW METER SOLVENT
1
2
3
4
5
TECNO
V/P
FLUID
PRESS.
SENS.
J4
SIG (RED)
COM (BLK)
+ PRESSURE (GRN)
COM (RED)
EX+ (WHT )
- PRESSURE (BLK)
SHIELD (BARE)
J11
V/P ANALOG OUT (WHT)
PRESS. (GRN)
+12 V (RED)
GND (BLK)
CHASSIS (BARE)
MH2
(10')/
(40')
I.S. METERS
6
5
4
3
2
1
J14
BLACK
RED
BLACK
RED
YELLOW
BLACK
AIR FLOW SWITCH 2
SOLVENT FLOW SWITCH
GFB 1 PRESSURE SWITCH
GFB 2 PRESSURE SWITCH
PURGE B
PURGE A
6
5
4
3
2
1
BLACK
RED
BLUE
BLACK
BLACK
RED
DUMP A
3RD FLUSH
MANIFOLD
6
5
4
3
2
1
BLACK
RED
BLACK
RED
BLACK
RED
DUMP B
GFB #1
GFB #2
12 VDC
3-WAY SOLENOID
J15
J8
12 VDC
4-WAY SOLENOID
1
2
3
4
5
6
J12
J13
1
2
3
4
5
6
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
GROUND
TERMINAL
J4
J6
NON-HAZARDOUS
AREA
HAZARDOUS
AREA
CABLE
BLUE
CABLE
(50' STD.)/
(100' OPTION)
10' STD.
(25'-100' OPTIONS) - GREEN COLOR CODED
GRD (BLK)
+12VDC (RED)
SHIELD (BARE)
CAN H (WHT )
CAN L (BLU)
3
2
5
4
1
J7
3
2
5
4
1
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
50' STD.
(10'-100' OPTIONS) - RED COLOR CODED
12 VDC
4-WAY SOLENOID
PROMIX 3KS
PS & BARRIER
INTERFACE
PROMIX 2KS
EASYKEY
INTERFACE
TO FO IN (BLK) - J7
TO FO OUT (BLU) - J8