User's Manual

Setup Mode
32 313885C
Option Screens
NOTE: See FIG. 24 on page 28 for a map of the Option
Screens. Detailed screen descriptions follow.
NOTE: Each screen displays the current screen number
and the total number of screens in the group.
Option Screen 1
Flush Volume Check
This field only appears if Solvent Monitor is set to
“Meter” in Configure Screen 5, page 31.
If set to “On”, Minimum Flush Volume will appear in Rec-
ipe Setup Screen 2, page 40.
Flush and Fill Input
If set to “Global”, Color/Catalyst Purge and Color/Cata-
lyst Fill are added to Advanced Setup Screen 1, page
35. Advanced Setup Screen 2, 3, and 5 are added.
See pages 36-38.
If set to “Recipe”, Color/Catalyst Purge and Color/Cata-
lyst Fill are added to Recipe Setup Screen 2, page 40.
Recipe Setup Screen 3, 4, and 7 are added. See
pages 41-42.
K-Factor Input
If set to “Global,Advanced Setup Screen 4, page 37 is
added.
If set to “Recipe,Recipe Setup Screen 5, page 42, is
added.
Minimum Material Fill Volume
Enter 0-9999 cc.
Stage Fill Volume
This field refers to the amount of material that is
required to fill the mixed material line from the A/B fluid
panel to the C fluid panel, before adding component C.
This value must be the same as the selected dose size.
Default is 50 cc.
Verification Screen
Verification
This screen appears if Flush and Fill Input or K-Factor
Input are changed from “Recipe” to “Global” in Option
Screen 1.
F
IG. 32. Option Screen 1
FIG. 33. Verification Screen