User's Manual

Alarms and Warnings
96 313885C
Alarms and Warnings
System Alarms
System alarms alert you of a problem and help prevent
off-ratio spraying. If an alarm occurs, operation stops
and the following occurs:
Alarm sounds.
Status bar on the EasyKey Display shows the alarm
E-Code with a description (see Table 13).
System Warnings
Table 13 lists the System Warning Codes. Warnings do
not stop operation or sound an alarm. They are saved in
the date/time stamped log, which can be viewed on a
PC, using the ProMix 2KS Web Interface (see manual
313386).
To Reset Alarm and Restart
NOTE: When an alarm occurs be sure to determine the
E-Code before resetting it. See Table 13. If you forget
which E-Code occurred, use the Alarms Screens (page
24) to view the last 10 alarms, with date and time
stamps.
To reset alarms, see Table 14. Many alarms can be
cleared by simply pressing the Alarm Reset
key.
NOTICE
Do not use the fluid in the line that was dispensed off
ratio as it may not cure properly.
Table 13: System Alarm/Warning Codes
Code Description Details
E-1 Communication Error Alarm Page 97
E-2 Potlife Alarm Page 97
E-3 Ratio High Alarm Page 98
E-4 Ratio Low Alarm Page 99
E-5 Overdose A/B Dose Too Short Alarm Page 100
E-6 Overdose B/A Dose Too Short Alarm Page 100
E-7 Dose Time A Alarm Page 101
E-8 Dose Time B Alarm Page 101
E-9 Mix in Setup Alarm Page 102
E-10 Remote Stop Alarm Page 102
E-11 Purge Volume Alarm Page 102
E-12 CAN Network Communication Error
Alarm
Page 103
E-13 High Flow Alarm Page 104
E-14 Low Flow Alarm Page 104
E-15 System Idle Warning Page 104
E-16 Setup Change Warning Page 104
E-17 Power On Warning Page 104
E-18 Defaults Loaded Warning Page 104
E-19 I/O Alarm Page 105
E-20 Purge Initiate Alarm Page 106
E-21 Material Fill Alarm Page 106
E-22 Tank A Low Alarm Page 106
E-23 Tank B Low Alarm Page 106
E-24 Tank S Low Alarm Page 106
E-25 Auto Dump Complete Alarm Page 107
E-26 Color/Catalyst Purge Alarm Page 107
E-27 Color/Catalyst Fill Alarm Page 107
E-29 Tank C Low Alarm Page 106
E-30 Overdose C Alarm Page 100
E-31 Dose Time C Alarm Page 101