User's Manual

Pause
22 332144C
Pause
To bring the hose and gun back to spray temperature
after a brief break, use the following procedure.
1. Engage piston safety lock or trigger safety lock.
2. Set function knob to Slow Recirc .
3. Set Recirc/Spray valves to Recirc until temperature
readouts come back up.
4.
If you stop spraying for more than 2 minutes when
using an impingement mix gun,
close gun fluid
valves. Doing this will keep the internal parts of the
gun cleaner and prevent crossover.
Refill Tanks
Material can be added to the tanks at any time. See Fill
Fluid Tanks, page 17.
NOTE: If you are operating at high temperatures or flow
rates, follow Pause instructions to bring tanks up to tem-
perature.
Fusion
Probler
1
2
3
4
5
6
7
8
9
10
0
+
-
ti21494a
ti21495a
Fusion
Probler
NOTICE
To prevent cross-contamination of fluids and equip-
ment parts, never interchange ISO and RES parts or
containers.
Have at least two 5 gal. (19 liter) pails to transfer fluid
from drums to supply tanks. Label one pail “ISO” and
the other “RES”, using the red and blue labels pro-
vided. Always double-check which material you have
before pouring it in the supply tanks. Pouring is easier
if pails are not filled to the top.
Open only one supply tank at a time, to avoid splash-
ing material from one tank into the other when filling.