User's Manual

Maintenance
24 332144C
Maintenance
Check pump wet-cups fluid level daily, page 17.
Throat u-cup is not adjustable. Do not overtighten
packing nut/wet-cup.
Keep component ISO from exposure to moisture in
atmosphere, to prevent crystallization.
Wipe supply tank lid o-ring, inner rim, and inner tank
walls daily to prevent ISO crystallization. Keep film
of grease on o-ring and inside of lid.
Check desiccant filter weekly. Filter is blue when
fresh, and turns pink when saturated.
Remove plug (X) and clean fluid inlet strainer (S) as
needed. Always clean the fluid inlet strainers after
flushing.
Generally, flush if you will shutdown for more than
three days. Flush more often if material is moisture
sensitive and humidity is high in the storage area, or
if material may separate or settle out over time.
If using an impingement mix gun,
close gun fluid
valves when not spraying. Doing this will keep the
internal parts of the gun cleaner and prevent cross-
over. Clean gun mix chamber ports and check valve
screens regularly. See gun manual.
If using an Fusion Air Purge impingement mix gun,
always grease the gun after use until purge air car-
ries grease mist out the front of the gun. Use Part
No. 117773 Grease. See gun manual.
X
S
ti21836a
Fusion
Probler