User's Manual

Troubleshooting
10 332453C
Troubleshooting
1. Follow Pressure Relief Procedure in the Exact-
aBlend AGP Advanced Glazing Proportioner,
Setup-Operation manual before checking or repair-
ing gun.
2. Check all possible problems and causes before dis-
assembling gun.
Problem Cause Solution
Light Tower
Light does not blink green, red, and
off in sequence when the machine
is first turned on.
Bad connection or cable Ensure cable is connected or
replace the cable.
Bad light stack. Replace light stack.
S100 Low Level Sensors
The sensor does not activate. The low level sensor option has not
been activated on the DM.
Navigate to Screen 1 and activate
the low level sensor option.
The sensor has not been mounted
correctly.
Adjust the sensor until it is activated
by the collar.
The collar has been installed too
high on the shaft.
Lower the collar until the sensor is
activated.
Bad connection or cable Ensure cable is connected or
replace the cable.
Bad sensor Replace sensor.
USB Kit
Screen 4 does not show the USB
option.
Bad connection or cable. Ensure cable is connected or
replace the cable.
Bad GCA components. Replace the GCA components.