Repair Kit 334201A Air Controls EN Integrated Air Controls for Therm-O-Flow® 20 and 200 Systems. For professional use only. Important Safety Instructions Read all warnings and instructions in this manual and in related manuals. Save these instructions. See page 2 for model information and maximum working pressure. PROVEN QUALITY. LEADING TECHNOLOGY.
Models Kit No. Description Maximum Regulated Working Air Inlet Size Pressure 24W870 Integrated Air Controls for TOF20 and TOF200 125 psi (0.8 MPa, 8.
Repair Repair 3. Remove spring (5c), valve plate (5d), and o-ring (5b). Note Remove 1. Relieve pressure. See system manual for instructions. 2. Disconnect all hoses and tubing from air control. 3. Remove 4 screws and washers. 4. 5. 6. 7. Note the orientation of the director valve plate when you remove it. The opening should be on the opposite side (left) of the lever. Remove and discard pin (5g) and four valve seats (5e) with o-rings (5f).
Repair Replace Air Motor Regulator Replace Air Regulators 1. Relieve pressure. See system manual for instructions. 2. Disconnect air motor housing and fittings. 3. Remove two screws (9) and take off the shutoff valve (1) at top of module. If your system has an air solenoid, it can remain attached to the shutoff valve. 4. Remove two screws (9) and take off the air motor regulator (6). 5. Attach new regulator (6) to manifold.
Parts Parts 24W870 Air Control 334201A 5
Graco Information Ref 1 2 3 4 5 6 7 8 ▲ Part Description 121108 VALVE, shutoff (includes o-rings and screws) 101689 GAUGE, pressure, air; 0-200 psi (0-1.