User's Manual
RunUpControl
Run Run
Run
Up Up
Up
Control Control
Control
Run Run
Run
Up Up
Up
Setup Setup
Setup
1.Verifyrunupcontrollerrangeissetto100psi(10
Vinputsignalyields100psi).NOTE: NOTE:
NOTE:
settings
belowassumeinputairpressuretotheregulator
isgreaterthanorequalto100psi(simpliesrun
upprogrammingsothat%andpsivaluesare
interchangeable).
2.NavigatetoGeneralSetup(Screen4),page24,
anddisablePressureCompensation.
High High
High
Calibration Calibration
Calibration
Point Point
Point
1.TurnsystemONandrunlineatmaximumspeed.
2.NavigatetoLineMode(Screen2),page22,and
noteCurrentLineSpeedinFbelow.
3.Setpressureusingthepumppressuredialand
gaugeatthebaseoftheInvisiPacsystemuntil
thedesiredglueoutputisachieved.
4.NotepressuredisplayedonInvisiPacpump
pressuregaugeinG G
G
below.
5.Notepressuredisplayedonrunupcontrollerin
B B
B
below.
Low Low
Low
Calibration Calibration
Calibration
Point Point
Point
1.Reducelinespeedtominimumspeedandnote
CurrentLineSpeedinE E
E
below.
2.Reducepressureusingthedialandgaugeatthe
baseoftheInvisiPacsystemuntilthedesired
glueoutputisachieved.Notepressuredisplayed
onregulatorinC C
C
below.
3.ReturnpressureonInvisiPacpumppressure
gaugetovalueinG G
G
below.
User User
User
Setting Setting
Setting
Entry Entry
Entry
1.NavigatetoRunUpControl(Screens6–7,PC–8e
only),page26.Entersettingsinscreenshot
accordingtovaluesinsectionbelow.
2.NavigatetoGeneralSetup(Screen4),page
24andre-enablePressureCompensation.
User User
User
Settings Settings
Settings
(A) (A)
(A)
Maximumoutput_____100
%(psi)
(B) (B)
(B)
Runupcontroller
pressureathighline
speed
________
%(psi)
(C) (C)
(C)
Runupcontroller
pressureatlowline
speed
________
%(psi)
(D) (D)
(D)
Minimumoutput______50
%(psi)
(E) (E)
(E)
Lowlinespeed
________
ft/minor
m/min
(F) (F)
(F)
Highlinespeed
________
ft/minor
m/min
(G) (G)
(G)
InvisiPacpump
pressureathighline
speed
________
psi
PCSetup—RunUpControlscreenwithsettings
indicatedbythelettersabove.
334784A 31