User's Manual
Verication
Verication Verication
Verication
Thissectionveriesproperinstallationofthe
InvisiPacPatternControlSystem.Forfurther
assistance,seeTroubleshooting,page36.
Valves Valves
Valves
1.NavigatetoGunPurge,page18.
a.WithsystemON:attemptapurgeoneach
installedvalveandverifythatthevalveis
actuated(gluehasbeendispensedfromthe
appropriatevalve).
b.WithsystemOFF:disconnectthecable
fromthesolenoidandattemptapurge
oneachinstalledvalveandverifythatthe
signalisactuated(viatheLEDonthevalve
connector).
Triggers Triggers
Triggers
1.NavigatetoHome,page16.
2.Withoutproductinfrontofthetrigger,verifythat
thetriggerindicatorLEDisOFF.
3.Withproductinfrontofthetrigger,verifythatthe
triggerindicatorLEDisON.
Encoder Encoder
Encoder
1.NavigatetoHome,page16.
2.VerifythatthelinespeeddisplayedintheCurrent
LineSpeedindicator
ispositiveandvaries
fordifferentlinespeeds.
3.Ifthelinespeedshowndoesnotmatchthe
known/expectedvalue,seeCalibration,page34,
tomaketheappropriateadjustments.
Run Run
Run
Up Up
Up
Control Control
Control
1.NavigatetoHome,page16.
2.TurnthesystemONandwaitforthePattern
ControllertobecomeACTIVE.
3.Runthelineatvariousspeedsandverifythatthe
appropriateRunUpOutputisdisplayedonthe
screenandtheRunUpControllerisdisplayed(if
pressurereadoutisavailable).
4.Ifthepercentage/pressuredisplayeddoesnot
matchtheexpectedvalue,seeRunUpControl
(Screens6–7,PC–8eonly),page26,tomakethe
appropriateadjustments.
PLC PLC
PLC
Inputs Inputs
Inputs
1.NavigatetoHome,page16.
2.ActuatethePLCinputremotelyandverifythat
theexpectedresultisindicatedinthePLCIO
sectionintheupperrightcornerofthedisplay.
334784A 35