User's Manual
Troubleshooting
Display Display
Display
Problem Problem
Problem
Cause Cause
Cause
Solution Solution
Solution
SelectordialonPatternControl
boardsettowrongposition
IntegratedSystems:setto0
Stand-AloneSystems:setto1
Powernotturnedon
CheckforgreenlightonPatternControl
boardandDisplay
Displaydoesnotturnon
CommunicationcabledisconnectedVerifyPatternControlboardisconnected
toDisplay
SelectordialonPatternControl
boardsettowrongposition
IntegratedSystems:setto0
Stand-AloneSystems:setto1
PatternControlScreens
notpresent
SoftwareversionmismatchPerformsoftwareupdateprocess
withlatestversionofsoftware(see
SoftwareUpdateProcedure,page40).
RunUpControlScreens
notpresent
Encodersettingsnot
present
PC-8ekeytokennotinsertedinADMObtainPC-8ekeytoken(comeswith
PC-8eversionsofInvisiPacPatternControl
System)
Pattern Pattern
Pattern
Problem Problem
Problem
Cause Cause
Cause
Solution Solution
Solution
Valvenotassociatedwithcorrect
trigger(ornotassignedtoany
trigger)
Ensurevalvehasappropriatetrigger
selected
Physicalproblemwithvalve
See“NoGlueDispensed”troubleshooting
helpwithin
Valve
section
Improperstitchsettings
Stitch Interval
tooshortor
Stitch
Savings
toohigh
Wrong/emptyprogramselectedEnsureproperprogramisselectedon
PC Control – Program Storage
(see
ProgramStorage(Screen1),page17)
and
PC Control – Pattern Preview
(see
PatternPreview,page20)containsapattern
Nopatterndispensed
PatternControllernotACTIVETurnonpatterncontroller.Stand-Alone
systemswillgoACTIVEimmediately,
whereasIntegratedsystemswillgoACTIVE
oncetheInvisiPacsystemhasgoneACTIVE
Impropergun-triggeroffsetenteredEnsureappropriate
Gun - Trigger Offset
isenteredon
PC Setup – Event Map
(seeEventMap(Screen1),page21)
Patterndispensestoo
early/late
ImpropervalveOpen/Close
Compensation
/entered
Performcalibrationroutinefoundin
Calibration – Gun Compensation
(see
Calibration,page34)
Patternmeasurement
unitsareindistance/time
Improperlinemodeselected
Selectappropriatelinemodesettingon
PC
Setup – Line Mode
(see##)
334784A 37