Safety Instructions

AdvancedDisplayModule(ADM)Operation
System System
System
1 1
1
Usethisscreentosettheactivationpressureforthe
PressureImbalanceAlarmandDeviation,enableor
disablediagnosticscreens,setthemaximumand
minimumdrumvolume,andenabledrumalarms.
System System
System
2 2
2
UsethisscreentoenableManualHoseMode
andinletsensors,aswellassettingtheinlet
sensorlowpressurealarmandlowtemperature
deviation.ManualHoseModedisablesthehose
temperatureRTDsensorsothesystemcan
operateifthesensorsweretomalfunction(see
ManualHoseHeatMode,page51formore
information).Defaultsettingsare10psi(0.07MPa,
0.7bar)forlowinletpressurealarmand50˚F(10˚C)
forlowinlettemperaturedeviation.
System System
System
3 3
3
Usethisscreentoenablealternatepumpcylinder
sizes,toturnmotorstandbymodeonandoff,and
toenablerecirculationcyclecount.Cyclesbelow
700psioutletpressurewillnotbecountedunless
enabled.
36 334945B