Safety Instructions

Spraying
Spraying Spraying
Spraying
The Fusion AP gun is shown.
1.Engagegunpistonsafetylockandclosegun
󰘱uidinletvalvesAandB.
Fusion Fusion
Fusion
Probler Probler
Probler
2.Attachgun󰘱uidmanifold.Connectgunairline.
Openairlinevalve.
3.Adjustthegunairpressure.Donotexceed130
psi(0.2MPa,2bar).
4.SetPRESSURERELIEF/SPRAYvalves(SA,
SB)toSPRAY.
SB
SA
GA
GB
5.Verifyheatzonesareonandtemperaturesare
ontarget,seeHomescreen,page39.
6.Open󰘱uidinletvalve(FV)locatedateachpump
inlet.
7.Presstostartmotorandpumps.
8.Adjustpressurecompensatorknobtodesired
󰘱uidstallpressure.Turnknobclockwiseto
increasepressureandcounter-clockwiseto
decreasepressure.Usehydraulicpressure
gauge(HPG)toviewhydraulicpressure.Once
desired󰘱uidstallpressureisset,locktheknob
inplacebyrotatinglowerportionclockwiseuntil
tight.
ComponentAandBoutletpressureswillbe
higherthanthehydraulicsetpressure,depending
onthemodel.ComponentAandB(GA,GB)
pressuremaybeviewedonthepressuregauges
ortheADM.
334945B 49