User's Manual

Operation
3A0232R 19
Operation
Trigger Lock
Adjust AAC
If the spray pattern is not even, the AAC air pressure
may need to be adjusted. For all guns, the AAC air pres-
sure is set at the system. The external mix gun includes
an AAC air pressure adjustment on the gun also, see
AAC reference in F
IG. 7 on page 17. To increase AAC air
pressure on the external mix gun, turn knob coun-
ter-clockwise. To decrease air pressure, turn knob clock-
wise. For large changes in AAC air pressure, adjust the
pressure at the system.
Internal Mix Flush
NOTE: The recommended solvent line pressure is
80-100 psi (550-700 kPa, 5.5-7.0 bar).
After spraying, open the solvent knob (BC) to allow sol-
vent to flow through the gun. See F
IG. 7 on page 17.
While flushing, hold a metal part of the gun firmly to a
grounded metal pail.
High-pressure fluid from gun, hose leaks, or ruptured
components will pierce skin. This may look like just a
cut, but it is a serious injury that can result in amputa-
tion. Get immediate surgical treatment.
Do not point gun at anyone or at any part of the
body.
Do not put your hand over the dispense outlet.
Do not stop or deflect leaks with your hand, body,
glove, or rag.
Follow Pressure Relief Procedure when you
stop dispensing and before cleaning, checking, or
servicing equipment.
Engage trigger lock whenever you stop spraying to
avoid accidental triggering.
Engage
Disengage
TI10442a
TI10441a
FIG. 9
Bad
Good