User's Manual

Models
3A0868G 3
Models
* ProMix 2KE hazardous location equipment manufactured in the United States, with serial number beginning with
A or 01, has ATEX, FM, and CE approvals, as noted. Equipment manufactured in Belgium, with serial number
beginning with M or 38, has ATEX and CE approvals, as noted.
See page 4 for models approved for non-hazardous locations.
ProMix 2KE systems are not approved for use in hazardous locations unless the base
model, all accessories, all kits, and all wiring meet local, state, and national codes.
Approved for Hazardous Location
Class 1, Div 1, Group D (North America); Class 1, Zones 1 and 2 (Europe)
Part No. Series Ratio Pumps
Maximum
Working Pressure
psi (MPa, bar)
USB
Port
Approvals*
24F102 A 3:1 Merkur, A and B 300 (2.1, 21)
24F103 A 23:1 Merkur, A and B 2300 (15.8, 158)
24F104 A 30:1 Merkur, A and B 3000 (20.6, 206)
24F105 A 45:1 Merkur, A and B 4500 (31.0, 310)
24F106 A 3:1
Merkur A,
Merkur Bellows B
300 (2.1, 21)
24F107 A 23:1
Merkur A,
Merkur Bellows B
2300 (15.8, 158)
24F108 A 35:1
Merkur A,
Merkur Bellows B
3500 (24.1, 241)
24F109 A 3:1 Merkur, A and B 300 (2.1, 21)
24F110 A 23:1 Merkur, A and B 2300 (15.8, 158)
24F111 A 30:1 Merkur, A and B 3000 (20.6, 206)
24F112 A 45:1 Merkur, A and B 4500 (31.0, 310)
24F113 A 3:1
Merkur A,
Merkur Bellows B
300 (2.1, 21)
24F114 A 23:1
Merkur A,
Merkur Bellows B
2300 (15.8, 158)
24F115 A 35:1
Merkur A,
Merkur Bellows B
3500 (24.1, 241)
Ex ia px IIA T3 Ta = 0°C to 54°C
FM10 ATEX 0025 X
#53
Intrinsically safe and purged equipment for
Class I, Division 1, Group D, T3
Ta = 0°C to 54°C
0359
II 2 G
See Special Conditions
for Safe Use in
Warnings, page 5.