User's Manual

Available Internal Data
10 3A1704G
System
Status
5 | DV Lockout / Circu-
lation Control
(1 = Locked out)
1-2 0 = Unlock Dis-
pense Valve,
Non-Circula-
tion State
1 = Lockout
Dispense Valve
, Circulation
State
1-2 0 = Dispense
Valve is
unlocked or in
Non-Circula-
tion State
1 = Dispense
Valve is
locked out or
in Circulation
State
Used to lock out the dispense valve
or configure to circulation mode (cir-
culation type system) when in
standby/operator or operator/night
modes only. Only for stall to pres-
sure systems with an electric dis-
pense valve or any stall to pressure
dispense valve configuration (circu-
lation type system).
6 | Mix head Cleanout
(1 = Closed)
0 = Open
Clean Out
1 = Close
Clean Out
0 = Clean Out
is open
1 = Clean Out
is closed
Used for L-Head systems cleanout /
diagnostics only.
7 | SYSTEM
STARTUP BIT
(1 = On)
Valid for Circulation
systems ONLY
0 = Stop Sys-
tem Startup
1 = Start Sys-
tem Startup
0 = System
Startup OFF
1 = System
Startup ON
System Startup bit will initiate a con-
trolled startup of the system. The
temperature conditioning zones will
be initiated when the bit is high. Low
pressure recirculation is also
enabled when the bit is set (Standby
and night modes). Turning off this bit
will turn OFF the temperature condi-
tioning zones and circulation. For
stall to pressure systems with a
manual dispense valve, setting this
bit will configure the pumps to stall
to the pressure set point. For stall to
pressure systems, set to operator
mode and set the DV Lockout / Cir-
culation Control bit to high. Setting
this bit will start a recirculation dis-
pense for recirculation type sys-
tems.
8 | Not Used Not Used Not Used Not Used
9 | Prime Side
(1 = Blue)
0 = RED
1 = BLUE
0 = RED
1 = BLUE
Selects which pump- Red or Blue-
to dispense from in prime mode.
Used for priming the chemical thru
the pumps and hoses. Valid for
VRM/VPM, Infusion/Paste systems
only. Initiating a Prime shot is via the
ADM or the Footswitch. Chemical
will dispense out of the Ratio check
valves if the system is not setup for
circulation.
Units
In
Byte
CGM Input
from PLC
Output
Out
Byte
CGM Output
to PLC Input Descriptions