User's Manual
Available Internal Data
3A1704G 11
10 | Base Purge
(1 = On)
0 = Park Pump
ON
1 =Base Purge
ON
0 = Park
Pump ON
1 =Base
Purge ON
Park mode is valid for all machine
configurations. Material will dis-
pense out of the mixer for all non cir-
culating systems. Circulating
systems can be parked without dis-
pensing material.
Base purge is valid for VRM/VPM
systems only. Material will be dis-
pensed out of the ratio check ports.
System
Status
11 | Recirc Status
(1 = High Pressure
Recirc)
1-2 0 = Low Pres-
sure circula-
tion ON
1 = High Pres-
sure circula-
tion ON
1-2 0 = Low Pres-
sure circula-
tion ON
1 = High Pres-
sure circula-
tion ON
Valid for full circulation systems
only. Indicates status of the pump-
ing system when in circulation. If
system is in low pressure recirc the
pumps will shift to High pressure
circ and then start the pre-dispense
time. When the pre-dispense time
expires, user can request dis-
penses. After expiration of post-dis-
pense time, the system will return to
low pressure modes. Pre and post
dispense times are settable on the
ADM system-2 sub screens.
12 | Purge Alarm
(1 = Purge Active)
-- 0 = Purge
shot not
Active
1 = Purge
Shot Active
Monitoring Only. Indicates status of
the purging routine.
13 | PLC Disables dis-
pensing
0 = Enable Dis-
pensing
1 = Disable dis-
pensing
0 = Dispens-
ing Enabled
1 = Dispens-
ing Disabled
PLC enables / disable dispensing
from the GCA controller / footswitch
or remote start via the MCM.
14 | CGM Control
Enabled
0 = ADM has
control of the
system
1 = CGM has
control on the
system
0 = CGM can
only monitor
1 = CGM can
control the
system
Select via the PLC the control of the
system from either the CGM or the
ADM. CGM can monitor status in
either mode.
15 | USED INTER-
NALY
-- --
Units
In
Byte
CGM Input
from PLC
Output
Out
Byte
CGM Output
to PLC Input Descriptions