User's Manual

Available Internal Data
12 3A1704G
Operating
Mode
System Mode Select 3 DISABLED
Mode = 1
3 DISABLED
Mode = 1
PLC selects the various modes of
the dispensing system.
CGM feedbacks the status of the
system to the PLC.
Prime mode is only available for
variable ratio systems.
Night mode is only available on
standard HFRs with full circulation
systems.
If using a manually controlled dis-
pense valve, shot and sequence
modes are not available.
STANDBY
Mode = 2
STANDBY
Mode = 2
SHOT Mode=
3
SHOT Mode=
3
SEQUENCE
Mode = 4
SEQUENCE
Mode = 4
OPERATOR
Mode = 5
OPERATOR
Mode = 5
PRIME Mode =
6
PRIME Mode
= 6
NIGHT Mode=
7
NIGHT
Mode= 7
Selected
Shot
Select Shot number,
or Sequence Position
Number
4 In Shot Mode,
Selects the
Active Shot
number. In
Sequence
Mode, selects
the Active
Sequence
position num-
ber.
4 Shot or
Sequence
number feed-
back
Select, via the PLC, the active shot
number when in Shot mode or the
Current Sequence position number
when in Sequence mode
Selected
Sequence
Select sequence 5 In Sequence
mode, selects
that active
sequence. Is
ignored in
other modes
5 Sequence
selected feed-
back
Select via the PLC the active
sequence when in Sequence mode
Condition-
ing / Heat
zones
6 Bit 0 = 1, Red
Tank heat
enable
6 Bit 0 = 1, Red
Tank heat ON
PLC enables / disable the various
Conditioning Zones.
Setting the bit = 1 enables the Heat
Zone.
Setting the bit = 0 disables the Heat
Zone.
Feedback: 0 = zone OFF, 1 = Zone
ON
Bit 1 = 1, Blue
Tank heat
enable
Bit 1 = 1, Blue
Tank heat ON
Bit 2 = 1, Red
Inline heat
enable
Bit 2 = 1, Red
Inline heat ON
Bit 3 = 1, Blue
Inline heat
enable
Bit 3 = 1, Blue
Inline heat ON
Units
In
Byte
CGM Input
from PLC
Output
Out
Byte
CGM Output
to PLC Input Descriptions