Bit | Function
-- -- 13-14 Bit
xx | Meaning
0-1 | Volume Units -- 0 0 | Gallons;
0 1 | cc's; 1 0 |
Liter
Monitoring Only. The operating units
of the machine can be read into the
PLC and used as required.
2 -3 | Weight Units -- 0 0 | grams; 0
1 | kilo-
grams;
1 0 | pounds
4-5 | Pressure Units -- -- 13-14 0 0 | bar; 0 1 |
psi; 1 0 | MPa
Monitoring Only. The operating units
of the machine can be read into the
PLC and used as required.
6 | Temperature -- 0 = Fahren-
heit; 1 = Cel-
sius
7 | Flow Unit -- 0 = Volume; 1
= Weight
8 | Rate Unit -- 0 = Minute; 1
= Second
9 | Control Mode -- 0 = Pressure;
1 = Flow
10 11 | Dispense
Mode
-- 0 0 | Time; 0 1
| Volume; 1 0 |
Weight
12 | Reserved for
future use
-- --
13 | Reserved for
future use
-- --
14 | Reserved for
Future use
-- --
15 | Reserved for
future use
-- --
Flow rate
setpoint
Depending on system
setup the units can be
by weight or volume
-- -- 15-18 Integer value
of the Flow
rate setpoint
in the dis-
pensing sys-
tem.
Monitoring Only. The value from the
CGM is an integer and must be mul-
tiplied by 0.0001 for the requested
flow rate to be in system units
Dispense
amount
setpoint
Depending on system
setup the units can be
by weight, volume, or
time
-- -- 19-22 Integer value
of the Dis-
pense amount
setpoint in the
dispensing
system.
Monitoring Only. The value from the
CGM is an integer and must be mul-
tiplied by 0.001 for the requested
amount to be in system units
Units
In
Byte
CGM Input
from PLC
Output
Out
Byte
CGM Output
to PLC Input Descriptions