User's Manual

Available Internal Data
3A1704G 15
Ratio of
the Blue /
Red mate-
rial - set-
point
Depending on system
setup the units can be
by weight or volume
-- -- 23-24 Integer value
of the Blue /
Red Material
Ratio setpoint
in the dis-
pensing sys-
tem.
Monitoring Only. The value from the
CGM is an integer and must be mul-
tiplied by 0.01 for the requested
material Ratio to be in system units
Blue is the value and Red is always
= 1. Blue: Red == xx.xx:1
Pump Red
Pressure -
Actual
PSI, bar, or MPa -- -- 25-28 Integer value
of the actual
Red pump
pressure in
the dispens-
ing system.
Monitoring Only. The value from the
CGM is an integer and must be mul-
tiplied by 0.0001 for the actual Red
pump pressure to be in system units
Pump
Blue Pres-
sure -
Actual
PSI, bar, or MPa -- -- 29-32 Integer value
of the actual
Blue pump
pressure in
the dispens-
ing system.
Monitoring Only. The value from the
CGM is an integer and must be mul-
tiplied by 0.0001 for the actual Blue
pump pressure to be in system units
Pump
Flow -
Actual
Depending on system
setup the units can be
by weight or volume
-- -- 33-36 Integer value
of the actual
Flow rate in
the dispens-
ing system.
Monitoring Only. The value from the
CGM is an integer and must be mul-
tiplied by 0.0001 for the actual flow
rate to be in system units
Ratio of
the Blue /
Red mate-
rials
-Actual
Depending on system
setup the units can be
by weight or volume
-- -- 37-38 Integer value
of the actual
Material Ratio
in the dis-
pensing sys-
tem.
Monitoring Only. The value from the
CGM is an integer and must be mul-
tiplied by 0.01 for the Actual material
Ratio to be in system units. Blue is
the value and Red is always = 1.
Blue: Red == xx.xx:1
Dispense
Amount -
Actual
Depending on system
setup the units can be
by weight or volume
-- -- 39-42 Integer value
of the actual
Dispense
amount in the
dispensing
system.
Monitoring Only. The value from the
CGM is an integer and must be mul-
tiplied by 0.001 for the actual
amount to be in system units
Dispense
Duration
-Actual
mS -- -- 43-46 Actual Dura-
tion of the dis-
pense in mS
Monitoring Only. Time base is 0.001
seconds == xxx ms.
Blue Inline
Temp -
Actual
Depending on system
setup the units can be
read in C or F
-- -- 47-48 Actual tem-
perature
Monitoring Only. The value from the
CGM is an integer and must be mul-
tiplied by 0.1 for the actual tempera-
ture to be in system units.
Blue Hose
Temp -
Actual
Depending on system
setup the units can be
read in C or F
-- -- 49-50 Actual tem-
perature
Red Inline
Temp -
Actual
Depending on system
setup the units can be
read in C or F
-- -- 51-52 Actual tem-
perature
Units
In
Byte
CGM Input
from PLC
Output
Out
Byte
CGM Output
to PLC Input Descriptions