User's Manual

Setup
3A2175A 31
4. Connect regulator assemblies (If Equipped)
NOTE: Systems equipped with a fluid regulator on the
material inlet will not be fully assembled due to shipping.
The regulator assembly will be detached and boxed
separately.
a. Attach the male nipple located on the regulator
assembly to the female swivel located on the
end of the pump assembly.
b. Connect the air tube to the tee fitting on the
power valve assembly located on the right side
of the machine.
5. Connect feed pumps (HFRL)
a. Install feed pumps in component A (Red) and B
(Blue) supply drums. See F
IG. 1 and FIG. 4,
pages 16 and 19.
NOTE: A minimum feed pressure of 50 psi (0.35 MPa,
3.5 bar) is required at both feed inlet pressure gauges
(FP). Maintain A (Red) and B (Blue) feed pressures
within 10% of each other.
b. Ensure A (Red) and B (Blue) inlet valves (FV)
are closed.
c. Adjust the fluid pressure regulator so the pres-
sure gauge reads zero.
NOTE: Supply hoses from feed pumps should be 3/4 in.
(19 mm) ID minimum.
d. Connect and tighten component B (Blue) supply
hose to the 3/4 npt(f) swivel on the component B
(Blue) inlet assembly.
e. Connect and tighten component A (Red) supply
hose to the 3/4 NPT(f) swivel on the component
A (Red) inlet assembly.
pressure
ti18216a
gauge
250 psi max inlet
pressure
3000 psi max
inlet pressure
ti9883a1
FV
ti18217a