User's Manual

Setup
32 3A2175A
6. Connect pressure relief lines (R)
a. Recommended: Connect high pressure hose
(R) to relief fittings (BA, BB) of both PRES-
SURE RELIEF/DISPENSE valves. Secure sup-
plied bleed tubes (N) in grounded, sealed waste
containers (H). See F
IG. 1, page 16.
7. Connect hose
a. Turn main power OFF .
b. Assemble fluid supply hose sections and whip
hose.
c. Connect A (Red) and B (Blue) hoses to A (Red)
and B (Blue) outlets on HFR fluid manifold (FM).
Hoses are color coded: red for component A,
blue for component B. Fittings are sized to pre-
vent connection errors.
8. Connect air tubes from solenoid valve to MD2.
a. Route the airlines following the material hoses.
Do not install shutoffs downstream of the PRESSURE
RELIEF/DISPENSE valve outlets (BA, BB). The
valves function as overpressure relief valves when set
to DISPENSE . Lines must be open so valves
can automatically relieve pressure when machine is
operating.
If circulating fluid back to the supply drums, use high
pressure hose rated to withstand the maximum work-
ing pressure of this equipment.
ti9880a1
BA
BB
R
R
SB
SA
NOTICE
To avoid improper machine operation, ensure the
open and close ports of the MD2 are connected to
the proper open and close ports of the valve.
OPEN
CLOSED
OPEN
CLOSED