User's Manual

Operation
3A2175A 35
Operation
Startup
1. Use feed pumps to load fluid
NOTE: The HFR is tested with oil at the factory. Flush
out the oil with a compatible solvent before dispensing.
See Flushing on page 39.
a. Check that all machine connections are setup.
See Setup procedure, page 29.
b. Verify both feed supply systems and the HFR
are connected to an air supply.
c. Verify the machine is ON.
d. If applicable, check that inlet screens are clean
before daily startup, see page 46.
NOTE: There are no inlet screens on systems equipped
with fluid pressure regulators.
e. If equipped, check level and condition of ISO
lube daily, see IsoGuard Select
System on
page 47.
f. Turn both PRESSURE RELIEF/DISPENSE
valves (SA, SB) to DISPENSE .
g. Start feed pumps.
h. Open fluid inlet valves (FV), if equipped. Check
for leaks.
i. Prime material regulators with fluid. Refer to
Adjusting Material Inlet Pressure Using the
Material Regulator on page 40.
j. Use feed pumps to load system.
k. Hold MD2 valve nose piece, without a mixer
installed, over two grounded waste containers.
Leave mixer off and trigger gun until both fluids
flow freely from the nose piece without any air.
l. To prime the pump, cycle the pump a few times
or until air-free fluid dispenses.
Do not operate HFR without all covers and shrouds in
place.
ti9877a1
SA
SB
Keep Components A (Red) and B (Blue) Separate
Cross-contamination can result in cured material in
fluid lines which could cause serious injury or damage
equipment. To prevent cross-contamination of the
equipment’s wetted parts, never interchange compo-
nent A (Red) and component B (Blue) parts.
FV
ti10002a1