User's Manual

Appendix B - ADM Setup Screens Overview
3A2175A 61
Calibration Screen, Specific Gravity
This screen allows the user to enter material specific
gravities and perform weight calibration shots. See Cali-
brate HFR on page 36 for how and when to use this
screen to calibrate the machine.
System Screen 1
This screen allows the user to set important system set-
tings. Control Mode can be set to Pressure or Flow. With
Control Mode set to Pressure, the machine will adjust
dispense flow rate in order to maintain the requested
pressure. With Control Mode set to Flow, the machine
will dispense at a continuous flow rate regardless of
pressure fluctuations unless pressure alarm conditions
occur.
Dispense Mode can be set to Time, Volume, or Weight.
Dispense Mode controls how displayed amounts are
measured. If Dispense Mode is set to Weight, then the
machine dispenses until the desired weight of material
is dispensed. See Calibrate HFR on page 36 for more
information.
Pump sizes and inlet pressures must be entered on this
screen.
If pump sizes and inlet pressures are not entered prop-
erly, system performance will be affected. The inlet pres-
sure must be set to the maximum feed pressure that will
be seen by that side of the machine.
The maximum working pressure for the machine is dis-
played on this screen. The maximum working pressure
is dependent on the installed hoses and dispense valve.
The maximum working pressure is set to the lowest
rated system component. If 2000 psi hoses are installed
and the maximum working pressure displayed is not
2000 psi, see manual 313998 for instructions to set the
maximum working pressure for hoses. If the installed
dispense valve rating is below the maximum working
pressure shown here, verify the correct dispense valve
is selected on System Screen 2.