User's Manual

Appendix B - ADM Setup Screens Overview
64 3A2175A
Maintenance Screen
This screen shows shot number and sequence position
counters. Press the Enter Screen button and navigate to
the drop down box. Press the enter key and scroll to a
range of counters to view. Press the enter key again to
select the range of counters and display them on the
screen.
Counters may be erased individually. Navigate to the
counter you want to erase and press the Erase Individ-
ual button. Alternatively, each counter displayed on the
page may be erased simultaneously by pressing the
Erase All button.
Supply Screen
This screen allows the user to specify the operating
parameters for off-board, integrated tanks and indicate
which positions have level sensors installed. See the
Tank Feed Systems manual for information about install-
ing level sensors, see Related Manuals on page 3. The
user may select from the following refill settings: Dis-
abled, Monitor, Manual, Auto Top-Off, Auto Full-Volume.
NOTE: Use the “Disabled” setting if off-board tanks are
not installed.
The following describes system operation when each
tank mode is selected.
Disabled
Disables tank operation
Monitor
The top sensor generates a high level deviation
and the bottom sensor generates a low level
alarm
Refill is not supported, no button is provided on
the run screens to initiate refill
Errors will clear when the corresponding condi-
tion clears
Manual
The low level sensor will generate a low level
alarm
A button is provided to the user on the run
screens to instigate a manual refill operation at
any time
Manual refill will run until either the high level
sensor sees material, the user aborts the refill
via the refill button on the run screens, or the
refill time-out expires
The low level alarm will clear when the condition
clears
Auto Top-Off
The low level sensor will generate a low level
alarm
When the high level sensor does not see mate-
rial, automatic refill will begin and continue until
either the high level sensor sees material or
until the refill time-out expires
The low level alarm will clear when the condition
clears
A button is provided to the user on the run
screens to instigate an automatic refill operation
at any time, this button can also be used to
abort a refill operation