Appendix B - ADM Setup Screens Overview
66 3A2175A
Conditioning Screen 2
This screen shows the fluid path for the temperature
conditioning components and temperature setpoints for
each component.
NOTE: If tank blanket heaters or inline heaters are
installed along with hose heat, the hose heat setting will
be limited to at or below the inline or tank heat setting.
To edit the temperature setpoint and alarms for a partic-
ular component:
1. Press the Enter Screen button and navigate to the
component you wish to edit.
2. Press the enter key to display the setpoint and
alarm values associated with that component.
3. Edit the setpoint and alarm values and then press
the page back button to return to the previous
screen.
Conditioning Screen 3
This screen allows the user to configure Night Mode
operation. In Night Mode, the system will cycle on and
off periodically. Press the Enter Screen button and
adjust the on and off durations as desired.
When the system is in Night Mode and in an “On” cycle,
the system will circulate in low pressure. The installed
conditioning zones will be on and controlling to their
respective setpoints. When the system is in Night Mode
and in an “Off” cycle, the system will be idle. The system
will not be circulating, and the conditioning zones will not
be actively controlling temperature. When in Night
Mode, supply tanks will not fill.
NOTE: Gray fields on this screen are items unavailable
at this time. Future product releases will incorporate
these features.
N
OTE: All components are shown installed for refer-
e
nce only. Only 4 components can be installed at one
t
ime.