User's Manual

Appendix C - ADM Run Screens Overview
70 3A2175A
Home Screen, Sequence Mode
This mode allows the user to select one of five
sequences (A-E). The progress bar on the bottom of the
screen shows the progress of a shot dispensing from
the selected sequence. See Sequences Screen on
page 59 for information about editing sequence defini-
tions.
To use a predefined sequence:
1. Ensure that the machine is in Sequence Mode.
2. Press the sequence letter/position selection button.
3. Use the left and right arrows to toggle between letter
and position selection. When selecting a sequence
letter (A-E), use the up and down arrow keys to
scroll through the available letters. When selecting a
sequence position, type in the desired position with
the numeric keypad. The system will reject invalid
letter/position selections.
4. Press the enter key to accept the sequence let-
ter/position.
5. Press the Dispense button to begin dispensing.
Home Screen, Operator Mode
This mode allows users to set a pressure or flow rate to
dispense material without using predefined shot infor-
mation. Pressure or flow rate availability is dependent
on the Control Mode selection, see System Screen 2
on page 62.
To edit the pressure or flow rate, press the button.
The value to change will now be highlighted. Type the
new value then press the Enter button to accept it.
The machine will begin dispensing at the set pressure or
flow rate when the dispense button is pressed and will
stop dispensing when it is pressed again. If a foot switch
is installed, the machine will dispense and continue to
dispense until the foot switch is released. If the foot
switch is used with a Mix Head installed a foot switch
press will start the pre-dispense timer and dispense
material when the timer expires. Another foot switch
press will terminate the dispense and start the post dis-
pense timer.
Ta r g e t
Flow/Pressure
Ratio
Target dispense amount (time/vol-
ume/weight depending on Dis-
pense Mode)
Total of resetta-
ble material
counters
B (Blue) reset-
table material
counter
A (Red) resetta-
ble material
counter
Operator
Setting
Ratio