User's Manual

Appendix C - ADM Run Screens Overview
3A2175A 73
Errors Screens
This screen shows users a list of errors that have
occurred in the system. Each error entry includes a
description and error code along with a date and time
stamp. There are 5 pages, each holding 10 errors. The
50 most recent errors are shown.
Refer to the Troubleshooting section on page 49 for a
detailed description of all of the system errors.
Events Screens
This screen shows users a list of events that have
occurred in the system. Each event includes a descrip-
tion and event code along with a date and time stamp.
There are 20 pages, each holding 10 events. The 200
most recent events are shown.
Refer to the Troubleshooting section on page 49 for a
detailed description of all of the system events.
Maintenance Screen 1
This screen displays historical information for each
pump in the system. The Batch counters are resettable
and count both material usage and pump cycles. The
Total counters are not resettable by the user. They also
count both material usage and pump cycles. For mate-
rial usage counters, units are displayed next to the vol-
ume/weight indicator icons.
To erase a batch counter, press the Enter Screen button
and navigate to the field to be erased. Press the Erase
Single button to erase that data point. Alternatively, the
Erase All button may be pressed to erase all of the batch
data points simultaneously.
NOTE: In a circulation system, the pumpline must be
stopped to erase counters.