User's Manual

Appendix D - ADM Error Codes
76 3A2175A
CAC1
Comm. Error
Motor
Communication error
Alarm
Loose/broken connection Check connection
CAC3
Comm. Error
Red Tank
Alarm
CAC4
Comm. Error
Blue Tank
Alarm
CAC5
Comm. Error
Mix Head
Alarm
CAC6
Comm. Error
Mix Head 2
Alarm
CAC7
Comm. Error
Ratio Monitor
Alarm
CAA6
Comm. Error
Red Blanket
Alarm
CAB5
Comm. Error
Blue Blanket
Alarm
CAA3
Comm. Error
Red Inline
Alarm
CAB1
Comm. Error
Blue Inline
Alarm
CAA2
Comm. Error
Red Hose
Alarm
CAB4
Comm. Error
Blue Hose
Alarm Module not programmed Program the module
CAA7
Comm. Error
Red Chiller
Alarm Module missing power Check power supply connection
CAB8
Comm. Error
Blue Chiller
Alarm Module bad Replace module
D1A1
Setpoint Not
Reached
The set point was not reached
and the pump was shutdown
Deviation
Material restriction too
high for requested flow
Reduce flow request
D2A1
Setpoint Not
Reached
The set point was not reached Deviation
Pump cannot reach the
requested pressure
Increase restriction in the system
Pump cannot reach the
requested flow
Decrease restriction in the system
D3A1
Setpoint
Exceeded
The set point was exceeded Deviation
System underwent a
change that caused a
large drop in restriction
(such as new orifices)
Erase learned System Data, found in the setup
screens under calibration
No material in pumps
Make sure the material lines are open and have
proper feed pressure
D5A1
Invalid Learn
Mode Data
This calibration lets the MCM
know where the ends of the
pump are. If the data gathered
during this process is outside
of normal parameters the
machine will operate with a
greatly reduced stroke.
Deviation
Recalibrate the machine Rerun the learn mode calibration
Loose/bad connection
Check to ensure the pressure transducer is properly
installed and all wires are properly connected
Bad linear position
sensor
Verify pump moves to limits, if problem persists
replace linear position sensor
D6A1
Position
Sensor Fault
The linear position sensor is
returning data that should not
be possible during normal
operation
Alarm
Loose/bad connection to
linear position sensor
Check to ensure the linear position sensor is properly
installed and all wires are properly connected
Bad linear position
sensor
Replace linear position sensor
Linear position sensor
may be loose where
attached to pump
housing
Re-tighten the sensor and re-calibrate the machine
DDA1
Red Pump
Cavitation
Cavitation was detected on the
given pump
Deviation
Insufficient material
being supplied or
insufficient material
pressure on feed system
Verify that incoming ball valves are open
DDB2
Blue Pump
Cavitation
Deviation Verify that feed pumps are supplying material
Debris or packout in the
incoming fluid filter
Inspect filter for debris of filler packout and clean or
replace as necessary
Error
Code Error Name Error Description
Error
Type Cause Solution