User's Manual

Technical Data
92 3A2175A
Technical Data
All other brand names or marks are used for identification purposes and are trademarks of their respective owners.
Maximum Fluid Working Pressure . . . 3000 psi (21MPa, 207 bar)
See Models starting on page 4 for specific information
Maximum Fluid Temperature . . . . . . . 120°F (50°C)
Fluid Inlet Pressure at Inlet Fitting:
HFRL Models . . . . . . . . . . . . . . . . 50 psi (345 kPa, 3.4 bar) to 250 psi (1.8 MPa, 18 bar)
HFRS Models . . . . . . . . . . . . . . . . 250 psi (1.8 MPa, 18 bar) to 3000 psi (21 MPa, 207 bar)
HFRS (Regulated Pressure). . . . . 250 psi (1.8 MPa, 18 bar) to 1500 psi (10 MPa, 103 bar)
Fluid Inlets . . . . . . . . . . . . . . . . . . . . . Component A (Red): 3/4 npt(f)
Component B (Blue): 3/4 npt(f)
Fluid Outlets on Manifold . . . . . . . . . . Component A (Red): 1/2 in. npt(f)
Component B (Blue): 1/2 in. npt(f)
Air Inlet. . . . . . . . . . . . . . . . . . . . . . . . 1/4 NPS
Air Inlet Pressure . . . . . . . . . . . . . . . . 40 psi (280 kPa, 2.8 bar) to 100 psi (0.7 MPa, 7 bar)
Fluid Circulation Ports . . . . . . . . . . . . 1/4 npsm(m), with plastic tubing, 250 psi (1.8 MPa, 18 bar) maximum
Line Voltage Requirement . . . . . . . . . 230V / 1 phase: 195-264V, 50/60 Hz
400V / 3 phase: 360-440V, 50/60 Hz
Amperage Requirement. . . . . . . . . . . See Models on page 4
Sound Power . . . . . . . . . . . . . . . . . . . 93 dB
Hydraulic reservoir capacity. . . . . . . . 8 gal. (30 liters)
Recommended hydraulic fluid . . . . . . Citgo A/W Hydraulic Oil, ISO Grade 46
Weight . . . . . . . . . . . . . . . . . . . . . . . . 634 lb (288 kg) (Not including supply pumps)
Wetted Parts . . . . . . . . . . . . . . . . . . . Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome,
fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically
resistant o-rings