User's Manual

Technical Data
3A2175A 93
Motor Control Module Technical Data
Overtemperature protection is provided to protect from motor overload.
Current limit, set via the software, is provided as a secondary protection from motor overload.
All installations and wiring must comply with NEC and local electrical codes.
Input Specifications
Input Line Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-264 Vac, line-to-line
Input Line Phasing . . . . . . . . . . . . . . . . . . . . . . . . . . . Single or Three Phase
Input Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . . 50/60 Hz
Input Current per Phase. . . . . . . . . . . . . . . . . . . . . . . 25A (three-phase), 50A (single-phase)
Maximum Branch Circuit Protection Rating: . . . . . . . 30A (three-phase), 63A (single-phase)
Short Circuit Current Rating. . . . . . . . . . . . . . . . . . . . 5 kA
Output Specifications
Output Line Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . 0-264 Vac
Output Line Phasing . . . . . . . . . . . . . . . . . . . . . . . . . Three Phase
Output Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-30A
Output Overload. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200% for 0.2 seconds
DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Vdc, Class 2, Graco-provided power supply
Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type 1
Max Ambient Temperature . . . . . . . . . . . . . . . . . . . . . . . . 50°C (122°F)