User's Manual

Troubleshootin
g
Code
Type Description Problem
Cause Solution
EQU3
Record
USB
Custom
Lang.
Downloaded
Custom Langua
ge was
downloaded to
USB
drive.
User installe
dUSB
device in ADM U
SB
port.
n/a
EQU4
Record
USB
Custom
Lang.
Uploaded
Custom Language was
uploaded from USB
drive.
User installed USB
device in ADM USB
port.
n/a
EQU5
Record
USB Logs
Downloaded
Data logs we
re
downloaded
to USB
drive.
User installed USB
device in ADM USB
port.
n/a
ES00
Advisory Factory
Defaults
Record of
defaults
being loa
ded.
n/a
EVUX Advisory
USB
Disabled
USB drive has been
inserted, downloading
is disabled.
Configuration of
system is blocking
data transfer.
Change configuration
to enable USB
download function.
There is
a restriction
on the o
utlet side of the
pump or
color stack.
Make sur
ethereare
no rest
rictions in the
color s
tack and that
the dum
pvalveis
actuat
ing.
F1F#
Alarm Flow Low
Fill Pu
mp #
There ha
s been no/low
flow dur
ing a ll pump
operat
ion.
Thick viscosity
paint requires more
pressure to pump.
Increase non-mix
pressure if necessary
to create flow during
the fill function.
F1S#
Alarm Flow Low
Purge
Pump #
There has been no/low
flow during a purge
pump operation.
Restriction in the outlet
side of the pump or
color stack resulting in
the solvent flow being
too low.
Make sure there are
no restrictions in the
system. Increase
non-mix pressure if
necessary to create
flow during the purge
function.
F6F#
Ala
rm
Pre
ss.
Sen
s.
Rem
oved
In
let #
Inl
et pressure
tra
nsducer has been
dis
connected when the
sy
stem is expecting
on
e.
Dis
connected
tra
nsducer.
Verify transducer
is connected
properly. Replace if
reconnecting does not
eliminate the alarm.
F
7D#
Alarm Flow
Detected
Pump #
T
he pump flow
e
xceeded 20 cc/min
ow coming into Idle
m
ode.
There is a leak in the
system or the gun was
open when the system
went into Idle mode.
V
erify there are no
l
eaks in the system.
M
ake sure the air flow
s
witch is actuating
p
roperly. Do not
t
rigger the gun without
atomizing air.
3A2800B
17